![Denyo GAW-185ES2 Instruction Manual Download Page 25](http://html1.mh-extra.com/html/denyo/gaw-185es2/gaw-185es2_instruction-manual_2485073025.webp)
Periodic inspection and maintenance
GAW-185ES2
- 39 -
3-4
After stopping
(1) In case it is intended that the welder will not be used for a certain length of time, be sure to remove
the starter switch key, and keep it in the specified position with care exercised not to lose it.
(2) Turn the fuel filter cock to the “CLOSE” position.
(3) Disconnect the welding cable. Disconnect cables and plugs from AC power outlets.
(4) Keep refueling the fuel tank. If left in a state in which the fuel in the fuel tank is low, water droplets
adhering fuel is evaporated, water accumulates in the fuel tank.
(5) Check out the loose bolts and nuts. Be retightened if there is nuts and bolts that are loose.
(6) Upon confirmation of complete cool-down of the welder, cover up the welder with a sheet or the like
and store the welder in a place of little humidity. Do not leave the welder in open air.