Periodic inspection and maintenance
GAW-185ES2
- 37 -
[Caution]
: Do not turn the starter switch while the engine is running.
▪
If abnormal vibration or abnormal noise was observed, stop the engine and carry out inspection.
Moreover, check for emission of black smoke or white smoke.
▪
Keep all the doors closed and keep the side door locked during running.
If any door is kept open, the welder may be damaged due to inclusion of foreign matters. In
addition, cooling conditions may become inferior due to changes in the airflow, and troubles may
result.
▪
Watch meters on the operation panel during running, and make sure that normal ranges are not
exceeded and no warning lamp is lit. If any warning lamp lights up, immediately stop the engine
and check the abnormal point.
▪
Make sure that the cumulative hour meter is working during running.
It starts working upon start-up of the engine.
▪
After the engine starts, let the machine idle for more than 5minutes to warm-up.
(1) Do not turn the starter (switch “Start” position) over than 10seconds.
If the machine fails to start despite repeating the starting procedure, there is obviously some
problem with the machine.
Therefore a thorough check is required (e.g. : Fuel has run out, forgetting to turn the fuel cock to the
open position and battery leakage)
(2) Recoil start
If the machine is could not to start by starter switch caused by battery leakage etc., Can be start by
the recoil start.
If using recoil start, the starter switch to “Run” position.
▪
Pull out the recoil starter knob slowly, make sure engaged latch of starter (pull the rope feel heavy)
and pull out strongly.
▪
After the engine is started, return to the recoil starter knob slowly.
(3) After the engine starts, let the machine idle for more than 5minutes to warm-up.
(4) If abnormal vibration or abnormal noise was observed, stop the engine and carry out inspection.
Moreover, check for emission of black smoke or white smoke.
(5) Keep all the doors closed and keep the side door locked during running. If any door is kept open, the
welder may be damaged due to inclusion of foreign matters. In addition, cooling conditions may
become inferior due to changes in the airflow, and troubles may result.
(6) Make sure that the cumulative hour meter is working during running. It starts working upon start-up
of the engine.