9 - 3 Checking/every 250 hours
(1) Replacement of engine oil
Replacement is refer to Г9-2.(1) Replacement of engine oil J ,
(2) Replacement of engine oil filter element
Replacement is refer to Г9 -2 ,(2 ) Replacement of engine oil filter element J
(3) Cleaning of air cleaner element
This element should be cleaned, regardless
of operating time, when the warning lamp of
"Air filter blinding" goes on.
— Dry dust clings on element ~
Remove the air cleaner element and dean
the element with dry and clean compressed
air.
* While it is being cleaned, check the element
for any damage. Replace if necessary.
* Before installing the air cleaner, wipe off dirt
on the element cover.
* When insert the element, insert the element
completely pressing equal edge of element.