background image

Nouveau depuis:

03.2021

CEREC AF, CEREC AF Connect
CEREC AI, CEREC AI Connect
CEREC AI for Rear

Notice d’utilisation (valable pour le Canada)

Français

Summary of Contents for CEREC AF Connect

Page 1: ...w as of Nouveau depuis 03 2021 CEREC AF CEREC AF Connect CEREC AI CEREC AI Connect CEREC AI for Rear Operating Instructions valid for Canada Notice d utilisation valable pour le Canada English Fran ai...

Page 2: ......

Page 3: ...1 09 English Fran ais CEREC AF CEREC AF Connect CEREC AI CEREC AI Connect CEREC AI for Rear Operating Instructions valid for Canada CEREC AF CEREC AF Connect CEREC AI CEREC AI Connect CEREC AI for Rea...

Page 4: ......

Page 5: ...New as of 03 2021 CEREC AF CEREC AF Connect CEREC AI CEREC AI Connect CEREC AI for Rear Operating Instructions valid for Canada English...

Page 6: ...ecting the unit 11 4 1 3 General safety information 12 4 1 4 Transporting the camera 12 4 1 5 Stability of the unit 13 4 1 6 Maintenance and repair 13 4 1 7 Modifications to the product 13 4 1 8 Acces...

Page 7: ...era 48 7 4 1 Occlusal scan 49 7 4 2 Buccal scan 49 7 4 3 Lingual scan 50 7 4 4 Approximal surface scan 50 7 4 5 Buccal registration 51 7 4 6 Scanning the quadrant and jaw 51 7 4 7 Completing measureme...

Page 8: ...lid for Canada 4 66 37 487 D3652 D3652 201 01 21 02 03 2021 8 1 2 9 High level disinfection of the mirror sleeve without HLD Set 65 8 1 2 10 Dry heat sterilization of the mirror sleeve 67 8 2 Calibrat...

Page 9: ...nstruction Improper use and handling can create hazards and cause damage Please therefore read and follow these operating instructions carefully Always keep them within easy reach Also pay attention t...

Page 10: ...ury and material damage please observe the warning and safety information provided in these instructions for use Such information is highlighted as follows DANGER An imminent danger that could result...

Page 11: ...on step Requests you to do something See Formats and symbols used 7 Identifies a reference to another text passage and specifies its page number List Designates a list Command menu item Indicates comm...

Page 12: ...7 D3652 D3652 201 01 21 02 03 2021 Symbols on the packaging Take note of the following symbols on the packaging Top Protect from moisture Fragile handle with care Temperature during storage and transp...

Page 13: ...eir changes NOTE CE mark for connected products Further products which are connected to this unit must also bear the CE mark Compliance Anyone creating or changing a medical electrical system in accor...

Page 14: ...tural appearing ceramic material The unit may be operated only by medically trained and qualified personnel This unit must not be used for any other purpose If the unit is used for any purpose other t...

Page 15: ...ed by a qualified expert in compliance with the national regulations DIN VDE 0100 710 applies in Germany WARNING Electric shock In order to prevent the risk of an electric shock this medical device mu...

Page 16: ...ear is Class B equipment classified according to CISPR 11 EN 60601 1 2 2015 based on IEC 60601 1 2 2014 This system may be operated in a residential area provided that it is used under the responsibil...

Page 17: ...his unit may be performed only by Dentsply Sirona or by agencies authorized by Dentsply Sirona Components which have failed and influence the safety of the unit must be replaced with original OEM spar...

Page 18: ...atient area a radius of 1 5m surrounding the patient CAUTION Low voltages are applied to the coupling box for connecting external interfaces Do not touch the pins of the connectors NOTE The externally...

Page 19: ...rona Operating Instructions valid for Canada 4 Safety 4 2 Safety labels 66 37 487 D3652 D3652 201 01 21 02 03 2021 15 English Heater plate CAUTION Risk of burns due to hot surface Never touch the heat...

Page 20: ...SD ESD stands for ElectroStatic Discharge ESD protective measures ESD protective measures include Procedures for preventing electrostatic charge build up e g air conditioning air moistening conductive...

Page 21: ...rge is perceptible at 3 000 V or higher audible at 5 000 V or higher cracking crackling visible at 10 000 V or higher arc over The transient currents resulting from these discharges have a magnitude o...

Page 22: ...2 D3652 201 01 21 02 03 2021 4 4 Wireless phone interference with equipment The use of mobile wireless phones in practice or hospital environments must be prohibited to ensure safe operation of the un...

Page 23: ...e can be disinfected by wiping High resolution 3D intraoral camera with control and image processing electronics Measuring technique Triangulation Light source White LED unpolarized visible spectral r...

Page 24: ...unit Type of protection against electric shock CEREC Omnicam camera Type BF applied part Degree of protection against ingress of water Ordinary device without protection against ingress of water Degre...

Page 25: ...EREC AF Connect Dimensions of the camera cradle W x H x D in mm in inches 278 x 102 5 x 73 10 15 16 x 4 1 32 x 2 7 8 Dimensions of the plate W x H x D in mm in inches 184 diameter 7 1 4 diameter Weigh...

Page 26: ...CEREC AI Connect A Recommended distances from cabinet or wall B Center of the floor cut out installation area C Minimum distance with tray and CEREC AI CEREC AI Con nect D Hazard warning The lamp inst...

Page 27: ...Dentsply Sirona Operating Instructions valid for Canada 5 Technical information 5 2 Technical data 66 37 487 D3652 D3652 201 01 21 02 03 2021 23 English...

Page 28: ...5 Technical information 5 2 Technical data Dentsply Sirona Operating Instructions valid for Canada 24 66 37 487 D3652 D3652 201 01 21 02 03 2021 Dimensions of CEREC AI for rear...

Page 29: ...he UNIT is intended for operation in the electromagnetic environment specified below The customer or user of the UNIT should make sure that it is used in such an environment Emission measurement Confo...

Page 30: ...to IEC 61000 4 5 1 kV differential mode voltage 2 kV common mode voltage 1 kV differential mode voltage 2 kV common mode voltage The quality of the line power supply should be that of a typical comme...

Page 31: ...equipment bearing the following graphic symbol Remark 1 The higher frequency range applies at 80 MHz and 800 MHz Remark 2 These guidelines may not be applicable in all cases The propagation of electr...

Page 32: ...nsmission frequency m 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz d 1 2 P d 1 2 P d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters w...

Page 33: ...ion immediately after delivery 1 Check the delivery note to ensure that the consignment is complete 2 Check whether the product shows any visible signs of damage NOTE Damage during transport If the pr...

Page 34: ...medical device includes the following main components CEREC Omnicam Camera for order with camera 65 34 767 D3652 Camera cradle 65 26 565 D3652 Coupling box 65 32 084 D3652 Medical power supply unit tw...

Page 35: ...5 37 158 D3652 FSP030 RFAM Input voltage range 100 240 VAC 50 60 Hz Input current range 1 0 0 6 A EDAC EM10681C Input voltage range 100 240 VAC 50 60 Hz Input current range 2 0 1 0 A CEREC AI The CERE...

Page 36: ...es 65 37 158 D3652 FSP030 RFAM Input voltage range 100 240 VAC 50 60 Hz Input current range 1 0 0 6 A EDAC EM10681C Input voltage range 100 240 VAC 50 60 Hz Input current range 2 0 1 0 A CEREC AI for...

Page 37: ...EC Omnicam delivered in case for CEREC AF and CEREC AF Connect x x x x x Calibration set x x x x x Camera cradle with ta ble base EBS table support x x x x without table base x without table base Coup...

Page 38: ...LAN cable x x x x x x x x USB 2 0 cable x x x x x x x x PC power cable x x x x x x x x Medical power supply unit cable x x x x x x x x Monitor power cable optional x x x x x x x x Optional 0 5 m came...

Page 39: ...n of how to switch the system on or off IMPORTANT Do not install an alternative virus scanner on your PC Microsoft Security Essentials has been pre installed 6 5 1 Controls and functional elements Cam...

Page 40: ...ents of monitor keyboard and mouse must be set up outside of the patient environment Enclosure color can also be white A ON OFF button B Air intake NOTE Use only the PC supplied by Dentsply Sirona The...

Page 41: ...NOTE The temperature inside the cabinet affects the performance of the PC Full performance can only be guaranteed up to a temperature of 35 C 95 F measured at the air intake of the PC A drop in perfo...

Page 42: ...he Omnicam A Press detent to release D Camera windows B Mirror sleeve E Calibration set C Sapphire glass coated NOTE CEREC Omnicam is calibrated The CEREC Omnicam is calibrated ex works see Calibratin...

Page 43: ...atment unit applies to CEREC AI CEREC AI Connect CAUTION Positioning camera cradle The camera cradle for the CEREC AF CEREC AF Connect must be placed on a flat horizontal surface either inside or outs...

Page 44: ...y insert the connector of the CEREC Omnicam cable into the coupling on the shorter of both cables at the camera cradle or the support arm cable of the CEREC AI AI Connect CEREC AI for Rear watching ou...

Page 45: ...e following applies for the optional integration of a 50cm extension cable 1 Carefully release the connection between the CEREC Omnicam cable and the camera cradle cable 2 Carefully insert the connect...

Page 46: ...initial installation Follow the steps below for proper operation after initial installation 1 Switch the PC on with the ON OFF button NOTE Possible data loss and PC malfunction Switching the PC off at...

Page 47: ...m in order to use the online help function Connecting the PC monitor via HDMI If you have connected your monitor to the PC via HDMI it may be the case that the image is surrounded by a black frame In...

Page 48: ...44 66 37 487 D3652 D3652 201 01 21 02 03 2021 6 5 4 Switching the units off NOTE Proper shutdown procedure The operating system must always be shut down properly to prevent data loss 1 Exit all progr...

Page 49: ...is not possible to carry out the exposure Following use always position the Omnicam on the heater plate You can set the end temperature to which the camera heater warms the Omnicam mirror sleeve 1 In...

Page 50: ...en operating continuously for more than 20 minutes in an ambient temperature of more than 30 C NOTE Image brightness The image brightness during the acquisition is controlled automatically so that the...

Page 51: ...ook around the patient s mouth 2 Remove the CEREC Omnicam from its holder As soon as the camera is pointed over a tooth or the gums data acquisition begins During the continuous data acquisition a col...

Page 52: ...can be heard If the registration cannot be implemented the acquisition flow is suspended You are informed of this by means of a sound This is different to the sound emitted during successful acquisiti...

Page 53: ...n To do so slowly move the CEREC Omnicam in the occlusal direction from the distal positioned tooth over the prepared tooth to the mesial positioned tooth With full jaw acquisitions the scan sequence...

Page 54: ...e approximal surfaces of the prepared tooth Move the CEREC Omnicam in the occlusal direction to the prepared tooth Acquire the approximal surfaces in the distal and mesial direction by using a wave mo...

Page 55: ...cal scan of the bite block prior to completing the registration This buccal scan should be carried out close up to the preparation To acquire sufficient geometry capture the teeth of the upper and low...

Page 56: ...ly Tilt the camera by 45 in a palatinal direction oral and guide it from the distal to the mesial 2 Tilt the camera another 45 in a palatinal direction oral and move it in a distal direction 3 Tilt th...

Page 57: ...a is only tilted by 45 in a palatinal direction oral moving from the distal and back to the mesial to the front teeth 3 Once you have reached the area of the front tooth guide the camera 45 to the buc...

Page 58: ...e using the cutter 7 4 7 Completing measurements The exposures are complete 1 Click on the Next button The virtual model is calculated and displayed in color Gray sections highlight data material that...

Page 59: ...cotton rolls or cheeks were unintentionally acquired When performing this activity be careful not to accidentally cut out any areas that e g are located behind the model or are otherwise cut away fro...

Page 60: ...must be immediately decommissioned Contact the customer service department for your dealer NOTE Annual maintenance performed by trained technical personnel is recommended 8 1 Care cleaning disinfectio...

Page 61: ...cal device and must therefore be handled with the utmost care Protect the coated sapphire glass and the camera windows against scratches and clean them with a clean lint free cloth and ethanol commerc...

Page 62: ...Press detent A NOTE There is a risk of damaging the camera windows or the coated sapphire glass if the mirror sleeve is not pushed straight toward the front Push the mirror sleeve straight toward the...

Page 63: ...otable water quality that meets Federal Clean Water Standards 4 Dry the mirror sleeve with a clean lint free cloth Dry heat sterilization process Dry heat 160 C Sterident Model 200 for 120 minutes wra...

Page 64: ...and mirror sleeve are disinfected through this step 3 Wipe down the mirror sleeve afterwards again with the absorbent cotton gauze dipped in drinking water 4 Next dry the mirror sleeve using a lint f...

Page 65: ...fore switching 4 Place the white protective cap on the camera tip and place the camera in the camera cradle 5 Use the following disinfectant for the high level disinfection CIDEX OPA 6 Slid the plug i...

Page 66: ...201 01 21 02 03 2021 8 Cautiously fill the HLD container up to the marked level B per manufacturer s instructions A funnel can be used to assist with filling the liquid A Do not spill any disinfectant...

Page 67: ...nutes in the disinfectant While exceeding the recommended immersion time may not cause damage to the mirror sleeve the mirror sleeve should be removed as soon as possible after the recommended time 11...

Page 68: ...15 Dry the plug with a clean lint free cloth 16 Prior to each use of the HLD set test the solution for its effectiveness per manufacturer s instructions If not in use rinse container and holder and st...

Page 69: ...mirror sleeve 59 2 Remove the mirror sleeve from the CEREC Omnicam see Removing the mirror sleeve 58 3 Place the camera in its camera cradle 4 Use the following disinfectant for the high level disinf...

Page 70: ...the recommended immersion time may not cause damage to the mirror sleeve the mirror sleeve should be removed as soon as possible after the recommended time 9 Remove the mirror sleeve from the contain...

Page 71: ...ror sleeve using dry heat at 160 C for 120 minutes or for 60minutes unwrapped or wrapped Use only pouches which are suitable for dry heat sterilization cycle of at least 160 C 120minutes The CPAC Cox...

Page 72: ...stress or during first commissioning after storage in unheated or un air conditioned rooms temperature differences exceeding 30 C 85 F with temperature differences of over 15 C 60 F between the last...

Page 73: ...in a clockwise motion until it gently locks into place 4 Click on the OK button The measuring process starts The software prompts you to proceed to the next latching 5 Turn the screw counter clockwise...

Page 74: ...calibration process is continued Once the calibration is complete a message is displayed indicating this 3 Confirm the message by clicking the OK button The CEREC Omnicam is calibrated Error message...

Page 75: ...use the Omnicam test tool on my cerec com CEREC SW 4 5 Shade Detection You can find the serial number of the Omnicam on the upper side on the optics tube see arrow E in the figure below This is only...

Page 76: ...es on the inside of the color calibration set it must be carefully removed using compressed air Switch on the color analysis 1 In the software navigate to the system menu and click on the Configuratio...

Page 77: ...serial number printed on your color calibration set click on the Rescan QR Code button and scan the new QR code 4 Mount the color calibration set on the tip of the camera until it locks into place 5 C...

Page 78: ...se has been reduced to less than 2 years can only be used for one year after the container has been opened Write the date that the container was opened on the container after Opened on ___________ usi...

Page 79: ...tiate return of the electrical device please send a disposal request to enretec GmbH You have the following options here Use the Returning an electrical device button under the eom menu item on the en...

Page 80: ...be required due to technical improvements Sirona Dental Systems GmbH Sprache englisch Printed in Germany D3652 201 01 21 02 03 2021 Nr 130 402 Sirona Dental Systems GmbH Fabrikstr 31 64625 Bensheim G...

Page 81: ...Nouveau depuis 03 2021 CEREC AF CEREC AF Connect CEREC AI CEREC AI Connect CEREC AI for Rear Notice d utilisation valable pour le Canada Fran ais...

Page 82: ...3 Consignes de s curit g n rales 12 4 1 4 Transport de la cam ra 12 4 1 5 Stabilit de l appareil 13 4 1 6 Entretien et remise en tat 13 4 1 7 Modifications apport es au produit 13 4 1 8 Accessoires 1...

Page 83: ...7 4 1 Balayage occlusal 49 7 4 2 Balayage buccal 49 7 4 3 Balayage lingual 50 7 4 4 Balayage des surfaces proximales 50 7 4 5 Recalage buccal 51 7 4 6 Enregistrer les quadrants et la m choire 51 7 4 7...

Page 84: ...valable pour le Canada 4 66 37 487 D3652 D3652 201 01 21 03 03 2021 8 1 2 9 D sinfection de niveau lev de la douille miroir sans kit HLD 65 8 1 2 10 St rilisation l air chaud 67 8 2 Calibrer CEREC Om...

Page 85: ...on inad quate et une utilisation non conforme peuvent tre l origine de risques et de dommages Nous vous prions donc de lire la pr sente notice d utilisation en entier et de l observer scrupuleusement...

Page 86: ...tissements et consignes de s curit figurant dans le pr sent document Ces passages sont caract ris s par les mentions DANGER Danger imminent entra nant de graves blessures corporelles ou m me la mort A...

Page 87: ...mboles utilis s 7 Indique une r f rence un autre emplacement de texte et indique le num ro de page num ration Indique une num ration Instruction option de menu Indique des instructions options de menu...

Page 88: ...3652 D3652 201 01 21 03 03 2021 Pictogrammes sur l emballage Tenez compte des pictogrammes suivants sur l emballage Haut Prot ger contre l humidit Fragile manipuler avec pr cautions Temp rature de sto...

Page 89: ...modifications ATTENTION Marquage CE pour produits raccord s Les produits raccord s cet appareil doivent galement tre munis du marquage CE Conformit Quiconque monte ou modifie un syst me lectrom dical...

Page 90: ...ramique imitant l aspect naturel des dents La manipulation de l appareil doit tre assur e par un personnel sp cialis ayant b n fici d une formation m dicale L appareil ne doit pas tre utilis dans un...

Page 91: ...spect des prescriptions nationales sp cifiques Pour l Allemagne les prescriptions sont celles de la norme DIN VDE 0100 710 AVERTISSEMENT Choc lectrique Afin d viter tout risque de choc lectrique ce di...

Page 92: ...ur CEI 60601 1 2 2014 Cet appareil peut tre utilis dans des zones d habitation sous r serve de son utilisation sous la responsabilit d un sp cialiste du secteur m dical PRUDENCE En cas d endommagement...

Page 93: ...r alis s par Dentsply Sirona ou par des organismes mandat s cet effet par Dentsply Sirona Les composants d fectueux influant sur la s curit de l appareil doivent tre remplac s par des pi ces de rechan...

Page 94: ...r du patient PRUDENCE De tr s basses tensions sont pr sentes au niveau des contacts des douilles de la bo te de couplage pour le raccordement d interfaces externes Ne touchez pas les broches des conne...

Page 95: ...on valable pour le Canada 4 S curit 4 2 Autocollants de s curit 66 37 487 D3652 D3652 201 01 21 03 03 2021 15 Fran ais Plaque chauffante PRUDENCE Risque de br lure caus e par la surface chaude Ne touc...

Page 96: ...l tiquette d avertissement ESD 4 3 2 Mesures de protection ESD ESD ESD est l abr viation de ElectroStatic Discharge d charge lectrostatique Mesures de protection ESD Les mesures de protection ESD comp...

Page 97: ...avec le rev tement de la chauss e Hauteur de la charge La hauteur de la charge d pend de diff rents facteurs La charge est plus lev e quand l humidit de l air est faible elle est plus lev e pour les m...

Page 98: ...alors provoquer des dysfonctionnements ou m me la d faillance de l appareil Afin d viter un tel cas de figure ce danger est signal par l tiquette ESD c t du connecteur ESD est l abr viation de Electro...

Page 99: ...yage Cam ra orale 3D haute r solution avec lectronique de commande et lectronique de traitement d image Proc d de mesure Triangulation Source lumineuse DEL blanches non polaris es spectre visible Acqu...

Page 100: ...tion I Degr de protection contre les chocs lectriques cam ra CEREC Omnicam Partie appliqu e de type BF Degr de protection contre la p n tration d eau Appareil courant sans protection contre la p n tra...

Page 101: ...C AF CEREC AF Connect Dimensions du support de la cam ra L x H x P en mm en pouces 278 x 102 5 x 73 10 15 16 x 4 1 32 x 2 7 8 Dimensions du disque L x H x P en mm en pouces 184 diam tre 7 1 4 diam tre...

Page 102: ...Connect A Distances recommand es par rapport l armoire ou au mur B Milieu de la perc e travers le sol zone d installation C Distance minimale avec tray et CEREC AI CEREC AI Connect D Danger La plage d...

Page 103: ...Dentsply Sirona Notice d utilisation valable pour le Canada 5 Informations techniques 5 2 Caract ristiques techniques 66 37 487 D3652 D3652 201 01 21 03 03 2021 23 Fran ais...

Page 104: ...5 Informations techniques 5 2 Caract ristiques techniques Dentsply Sirona Notice d utilisation valable pour le Canada 24 66 37 487 D3652 D3652 201 01 21 03 03 2021 Dimensions de CEREC AI for Rear...

Page 105: ...ment dans l environnement lectromagn tique d crit ci apr s Le client ou l utilisateur de l APPAREIL doit garantir qu il sera utilis dans un environnement conforme cette description Mesure d missions C...

Page 106: ...er type Harmoniques sup rieures surge se lon CEI 61000 4 5 1 kV en mode diff ren tiel 2 kV en mode commun 1 kV en mode diff rentiel 2 kV en mode com mun La qualit de la tension d alimenta tion doit co...

Page 107: ...Hz on utilise la plage de fr quence sup rieure Remarque 2 Il se peut que ces directives ne soient pas applicables dans tous les cas La propagation des grandeurs lectromagn tiques est influenc e par de...

Page 108: ...50 kHz 80 MHz 80 MHz 800 MHz 800 MHz 2 5 GHz d 1 2 P d 1 2 P d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 Pour les metteurs dont la puissance nominale maxim...

Page 109: ...de r ception 1 A l aide du bordereau de livraison veuillez contr ler que la livraison est compl te 2 Assurez vous que l appareil ne pr sente pas d endommagements visibles ATTENTION Endommagements lor...

Page 110: ...3652 comprend les composants principaux suivants Cam ra CEREC Omnicam commande avec cam ra 65 34 767 D3652 Support de cam ra 65 26 565 D3652 Bo te de couplage 65 32 084 D3652 Bloc d alimentation m dic...

Page 111: ...30 RFAM Plage de tension d entr e 100 240 V CA 50 60 Hz Plage de courant d entr e 1 0 0 6A EDAC EM10681C Plage de tension d entr e 100 240 V CA 50 60 Hz Plage de courant d entr e 2 0 1 0A CEREC AI Le...

Page 112: ...FSP030 RFAM Plage de tension d entr e 100 240 V CA 50 60 Hz Plage de courant d entr e 1 0 0 6A EDAC EM10681C Plage de tension d entr e 100 240 V CA 50 60 Hz Plage de courant d entr e 2 0 1 0A CEREC A...

Page 113: ...CEREC AF AI conte nant x x x x x x x x CEREC Omnicam livr e dans le coffret pour CEREC AF et CEREC AF Connect x x x x x Kit de calibrage x x x x x Support de cam ra avec pied kit de montage Support de...

Page 114: ...m dical 24 V x x x x x x x x C ble LAN du PC x x x x x x x x C ble USB 2 0 x x x x x x x x C ble secteur du PC x x x x x x x x C ble secteur du bloc d alimentation m dical x x x x x x x x C ble secteu...

Page 115: ...PORTANT N installez pas d autre antivirus sur le PC Microsoft Security Essentials est pr install 6 5 1 El ments de commande et de fonctions Cam ra avec support ATTENTION La cam ra et son support peuve...

Page 116: ...03 2021 Le bo tier peut galement tre de couleur blanche A Touche MARCHE ARR T B Entr e d air ATTENTION Utilisez uniquement le PC fourni par Dentsply Sirona Le PC pour CEREC AF CEREC AI CEREC AF Connec...

Page 117: ...ture l int rieur de l armoire influe sur la performance du PC La performance maximale ne peut tre garantie que sous une temp rature de 35 C 95 F mesur e au niveau de l entr e d air du PC Une baisse de...

Page 118: ...le cran de verrouillage D Fen tre de la cam ra B Douille miroir E Set de calibrage C Plaquette en saphir sur face rev tue ATTENTION CEREC Omnicam est calibr e La CEREC Omnicam est calibr e en usine v...

Page 119: ...la bo te de couplage sur le sol La bo te de couplage ne doit pas tre install e dans le coffret de raccordement de l unit de traitement ceci vaut pour CEREC AI CEREC AI Connect PRUDENCE Installation d...

Page 120: ...urnie pour CEREC AI AI Connect CEREC AI for Rear N utilisez pas la CEREC Omnicam d un CEREC AC AC Connect ou d un CEREC AF AF Connect 2 Enfichez avec pr caution le connecteur du c ble de la CEREC Omni...

Page 121: ...onge de 50cm de long 1 D branchez avec pr caution la liaison entre le c ble de la cam ra CEREC Omnicam et le c ble du support de la cam ra 2 Enfichez avec pr caution le connecteur du c ble de la cam r...

Page 122: ...nternet de Sirona Confirmez l actualisation du firmware de CEREC Omnicam par OUI Apr s la premi re installation Les tapes suivantes sont n cessaires pour un fonctionnement correct apr s la premi re in...

Page 123: ...en ligne qui peut tre appel e via F1 ou depuis l option de menu Aide ATTENTION Pour utiliser l aide en ligne la version 5 0 d Internet Explorer doit tre install e sur votre syst me Raccordement du mo...

Page 124: ...21 6 5 4 Mettre les appareils l arr t ATTENTION Quitter le syst me d exploitation selon la proc dure correcte Afin d viter la perte de donn es le syst me d exploitation doit tre mis l arr t selon la p...

Page 125: ...as une prise d empreinte n est pas possible Apr s utilisation reposez syst matiquement la cam ra Omnicam sur la plaque chauffante Vous pouvez r gler la temp rature finale laquelle le syst me de chauff...

Page 126: ...te de 30 C s lectionnez uniquement les trois niveaux inf rieurs de r glage du chauffage La temp rature de la surface de la douille miroir peut atteindre 51 C lorsque la cam ra fonctionne en continu pe...

Page 127: ...PREINTE La cam ra est op rationnelle Il appara t une image en temps r el l aide de laquelle vous pouvez vous orienter dans la bouche du patient 2 Pr levez la cam ra CEREC Omnicam de son support L acqu...

Page 128: ...correspondant Le flux de saisie est interrompu lorsque le recalage ne peut pas tre ex cut Le syst me vous en informe en mettant un son diff rent de celui mis pendant la prise d empreinte Le volume so...

Page 129: ...plus proche de la dent pr par e dans le sens distal 2 Effectuez un balayage dans le sens m sial D placez lentement la cam ra CEREC Omnicam en position occlusale depuis la dent distale vers la dent m s...

Page 130: ...une position linguale de 45 maximum 90 2 Guidez la cam ra CEREC Omnicam sur l ensemble de la distance en position linguale dans le sens m sial au dessus de la dent pr par e 7 4 4 Balayage des surface...

Page 131: ...points Balayage occlusal 49 Balayage buccal 49 et Balayage lingual 50 2 Avant le recalage final proc dez un balayage buccal du mordu occlusal Il convient de r aliser ce balayage buccal proximit de la...

Page 132: ...e Basculez la cam ra de 45 en position palatinale orale et d placez la dans le sens distal vers m sial 2 Basculez la cam ra de 45 suppl mentaires en position palatinale orale et d placez la en sens di...

Page 133: ...plac e de nouveau vers les dents ant rieures dans le sens distal vers m sial orient e de seulement 45 en position palatinale orale 3 Apr s avoir atteint le bloc ant rieur amenez la cam ra 45 du c t b...

Page 134: ...Boucler les mesures Les prises d empreinte sont compl tes 1 Cliquez sur le bouton Suivant Le mod le virtuel est calcul et repr sent en couleur Les surfaces grises signalent des donn es manquantes dan...

Page 135: ...ampons d ouate ou de la joue du patient Lors de la d coupe veillez ne pas d couper en m me temps par m garde des zones qui se trouvent p ex derri re le mod le ou qui sont coup es ailleurs par la ligne...

Page 136: ...imm diatement mis hors service Contactez le service client de votre revendeur ATTENTION Il est recommand de confier les travaux de maintenance annuelle du personnel technique form cet effet 8 1 Entre...

Page 137: ...extr mement sensible et ce titre doit toujours tre manipul avec le plus grandsoin Prot ger le verre en saphir et les fen tres de la cam ra contre les rayures et les nettoyer avec un tissu non peluche...

Page 138: ...e un risque d endommagement de la fen tre de la cam ra ou de la surface rev tue de la plaquette en saphir si la douille miroir n est pas pouss e tout droit vers l avant Pousser la douille miroir tout...

Page 139: ...e niveau lev conform ment aux consignes du fabricant 2 Laisser tremper la douille miroir dans le CIDEX OPA pendant 12minutes 20 C 3 Rincer la douille l eau du robinet de qualit potable qui r pond aux...

Page 140: ...t ainsi d sinfect s 3 Ensuite essuyez nouveau la douille miroir avec une gaze de coton imbib e d eau potable 4 S chez ensuite la douille miroir l aide d un chiffon non pelucheux 8 1 2 8 D sinfection d...

Page 141: ...capuchon blanc de protection sur l extr mit de la cam ra et placer la cam ra dans son support 5 Utiliser le d sinfectant suivant pour une d sinfection de niveau lev CIDEX OPA 6 Ins rer le bouchon dans...

Page 142: ...D jusqu au rep re B conform ment aux consignes du fabricant Il est possible d utiliser un entonnoir pour aider au remplissage du liquide A Veiller ne pas renverser de produit d sinfectant En cas de re...

Page 143: ...ant Bien que le d passement du temps d immersion recommand n entra ne pas de dommages pour la douille miroir celle ci doit tre retir e d s que possible d s que la p riode d immersion recommand e est d...

Page 144: ...cheux propre 16 Avant d utiliser le kit HLD il convient de toujours tester l efficacit de la solution conform ment aux consignes du fabricant Lorsqu ils ne sont pas utilis s rincer le r cipient et le...

Page 145: ...ouille miroir de la cam ra CEREC Omnicam voir Retrait de la douille miroir 58 3 Placer la cam ra dans son support 4 Utiliser le d sinfectant suivant pour une d sinfection de niveau lev CIDEX OPA PRUDE...

Page 146: ...face rev tue de la plaquette en saphir orient e vers le bas 8 Laisser la douille miroir immerg e au moins 12 minutes dans le produit d sinfectant Si la douille miroir reste immerg e plus longtemps dan...

Page 147: ...r s che une temp rature de 160 C pendant 120 minutes ou 60 minutes non emball e ou emball e Utiliser exclusivement des poches appropri es au cycle de st rilisation par chaleur s che une temp rature d...

Page 148: ...dans des locaux non chauff s ou non climatis s diff rences de temp rature sup rieures 30 C 85 F en cas de diff rences de temp rature sup rieures 15 C 60 F entre le dernier calibrage et l utilisation d...

Page 149: ...ger enclenchement se produise 4 Cliquez sur le bouton OK Le processus de mesure est lanc Le logiciel vous demande de tourner pour passer au cran suivant 5 Tournez la vis dans le sens inverse des aigu...

Page 150: ...alibrage se poursuit Une fois le calibrage termin un message s affiche pour vous indiquer que le calibrage est complet 3 Confirmez le message avec le bouton OK La cam ra CEREC Omnicam est calibr e Mes...

Page 151: ...urs L analyse des couleurs n est possible qu avec une cam ra CEREC Omnicam partir d un certain num ro de s rie Pour contr ler la cam ra CEREC Omnicam utilisez l outil de contr le Omnicam sur my cerec...

Page 152: ...roit sec et l abri de la lumi re Il doit tre utilis avec une cam ra Omnicam d sinfect e car le kit de calibrage des couleurs proprement dit ne doit pas tre d sinfect En cas d accumulation de poussi re...

Page 153: ...ouveau le code QR et scannez le nouveau code QR 4 Montez le kit de calibrage des couleurs jusqu en but e sur l extr mit de la cam ra 5 Cliquez sur le bouton Ok Le processus de mesure est lanc Pendant...

Page 154: ...oit r duite moins de 2 ans ne peut tre utilis que pendant une ann e apr s ouverture du r cipient Inscrivez la date d ouverture l aide d un marqueur ind l bile sur le couvercle du r cipient apr s Opene...

Page 155: ...Allemagne Pour la reprise de l appareil lectrique envoyez une demande d limination la soci t enretec GmbH Vous disposez cet effet des possibilit s suivantes Sur le site Interne de la soci t enretec Gm...

Page 156: ...technique Sirona Dental Systems GmbH Sprache franz sisch Printed in Germany D3652 201 01 21 03 03 2021 Nr 130 402 Imprim en Allemagne Sirona Dental Systems GmbH Fabrikstr 31 64625 Bensheim Germany www...

Page 157: ......

Page 158: ...nts Sous r serve de modifications dues au progr s technique Sirona Dental Systems GmbH Sprache englisch franz sisch Printed in Germany D3652 201 01 21 09 03 2021 Nr 130 402 Sirona Dental Systems GmbH...

Reviews: