background image

iii

 

Customer Registration and Inquiries 

Customer Registration 

To allow us to provide our customers with comprehensive service and support, we request that all customers complete a 

Member Registration Form. Registered members will be offered the following privileges. 

 

The latest upgrade information

 

 

Free exhibition and event information for new products 

 

Free web-information service “QBdirect” 

QBdirect Service Contents 

Information searching 

service (FAQ) 

Offers detailed information on each product. 

Download service 

The latest OS systems for the SP1 Series, repair software, and sample programs can be 

downloaded. 

E-mail inquiries 

Product related queries can be sent in by e-mail. 

  Please note that these privileges may be subject to change without prior notice.. 
 

How to Register 

Access the URL below and follow the instructions provided. 

https://www.denso-wave.com/ 
 

Inquiries 

For inquires relating to products, please access our website https://www.denso-wave.com . 

Technical inquiries can be made at our exclusive website for registered users (QBdirect). 

Summary of Contents for SP1-QUBi

Page 1: ...RF Tag Handy Scanner SP1 QUBi User s Manual...

Page 2: ...ption on each indicator 3 1 3 Description on each buzzer 4 Chapter 2 Basic Operations 5 2 1 Loading the Batteries 5 2 2 Battery Charging 7 2 3 Powering ON OFF 11 2 4 Connecting the Host Terminal 11 2...

Page 3: ...2019 Copyright Extended Systems Inc 2000 2005 Portions copyright iAnywhere Solutions Inc 2005 2014 All rights reserved No part of this publication may be reproduced in any form or by any means without...

Page 4: ...cts do not infringe upon any patents or other intellectual property rights of other s however DENSO WAVE cannot be responsible for any patent or other intellectual property right infringement s or vio...

Page 5: ...nformation searching service FAQ Offers detailed information on each product Download service The latest OS systems for the SP1 Series repair software and sample programs can be downloaded E mail inqu...

Page 6: ...imminently lead to serious bodily injury or death if the instructions are not followed correctly WARNING Alerts you to those conditions which could cause serious bodily injury or death if the instruct...

Page 7: ...charge the battery in the vicinity of high temperature locations 60 C or higher such as a fire stove or under a scorching sun Do not use or store the battery in places exceeding the service or storag...

Page 8: ...any damage and the battery for damage and leakage Never use a damaged case Never use a damaged or leaked battery Do not insert any foreign materials into the battery Do not get the scanner wet or put...

Page 9: ...ught in other objects or entangled in rotating machinery Failure to do so could result in accident or injury Do not move your ear close to the speaker while the Buzzer is beeping Doing so could lead t...

Page 10: ...canner in places where a strong magnetic field is generated Failure to observe this may lead to the scanner malfunction due to magnetic force Keep the scanner away from radio waves and metallic object...

Page 11: ...eries etc Thin type battery with thin battery cover BT SP1LA C Prepare either of the these batteries Large capacity battery with large capacity battery cover BT SP1L C Communication unit CU SP1A Charg...

Page 12: ...orking The following environments can sometimes block wireless networking Metal objects or particles in the vicinity Metal walls around the area Excessive vibration The communications range of 10 m gi...

Page 13: ...soapy water always use a neutral detergent and wrung out thoroughly Never use organic solvents such as thinner or alcohol as this may cause the housing to be marred or paint to be peeled off Code rea...

Page 14: ...ole Trigger switch Push this switch when reading RF tag or code Power button Mode button Pairing button Push this button when connecting disconnecting Bluetooth Status indicator Illuminates in blue wh...

Page 15: ...les Bluetooth Press this button for three seconds or more when the pairing is enabled and then the paring will be disabled Mode button MODE Switches the pairing mode Press this button for three second...

Page 16: ...g Continuously Connection is completed Power indicator Green illuminating for 1 second Battery power level 40 or more Orange illuminating for 1 second Battery power level 39 to 10 Red illuminating for...

Page 17: ...me ON 80ms RF tag reading is completed Low freq short time 5times ON 70ms OFF 70ms RF tag communication error High freq short time 5times ON 70ms OFF 70ms Data transfer error High freq short time 5tim...

Page 18: ...ion indicated by the arrow Remove the battery cover 2 Confirm the direction of a battery and an electrode Insert the battery in the arrow direction and completely install it 3 Retract a strap for remo...

Page 19: ...store it if not using the scanner for an extended period of time When using the scanner be sure to attach the battery cover 5 When replacing batteries open the battery cover and pull out the battery u...

Page 20: ...ndard time when the temperature is at 25 C and it may vary according to the condition of operation 1 Connect the output plug of the AC adapter into the DC input connector of the CU Connect the AC adap...

Page 21: ...charging indicator turns green charging is completed Remove the spare battery from the CU Charging time It takes approximately for 4 hours for BT 180LA thin type battery and 8 hours for BT SP1L large...

Page 22: ...e a USB charger with the specified output rating Use a USB charger that is compliant or compatible with the USB IF standard Battery Charging Specification Rev 1 2 Failure to follow instruction may cau...

Page 23: ...it again A battery has not yet been fully charged even after the specified charging time Recharge it with a spare battery charging slot of CU Due to battery damage and battery life Replace a battery w...

Page 24: ...ode Pairing mode has master mode and slave mode It is set as the slave mode at the factory default Mode Operation Master mode Tries to connect to the host terminal that is connected last after the pow...

Page 25: ...on of the host terminal to enable the detection For details refer to the User s Manual of the host terminal 2 Power on the scanner and the pairing indicator will blink in blue and the Bluetooth functi...

Page 26: ...is approximately 6 X 4 cm Only one code can be contained in the readable area If there is more than one code in the readable area a scanner may not be able to scan codes or may continue alternate code...

Page 27: ...gain Code surface curvature Scanning may be unsuccessful if the code surface is curved Scan the barcode at the center of the barcode reading window Code surface dirt Scanning may be unsuccessful if it...

Page 28: ...the RF tag and then either start from the host user application or press the trigger switch The status indicator illuminates in red and the radio wave is emitted to the RF tag 2 When the reading writi...

Page 29: ...read the tag smoothly due to the protection from heating of internal parts This may not cause a problem If the sufficient reading performance is required however stop emitting the radio wave and retr...

Page 30: ...ctromagnetic cooking device etc Radio interference If there is any other RFID device near the scanner it may not be able to read write RF tags If the scanner is used near other radio devices such as a...

Page 31: ...Precautions for the handling of the battery to ensure the proper battery use Battery service life The battery is a consumable part And it should be replaced upon the earlier of one year or after bein...

Page 32: ...ttachment for BHT 1800 series separately sold Slide the attachment all the way to the end in the arrow direction along the rails on both sides of the scanner Check that the attachment is locked Insert...

Page 33: ...ergo any strong impact The malfunction of the host terminal and devices and defective data having been dropped or subject to impact are not guaranteed When attaching or removing the attachment be sure...

Page 34: ...attachment Do not drop or swing a scanner with the attachment installed or let it undergo any strong impact The malfunction of the host terminal and devices and defective data having been dropped or s...

Page 35: ...scanner terminals If the battery in use is an old one that has been repeatedly charged 300 times or more or if more than one year has elapsed replace it with a new one Problem The scanner unexpectedly...

Page 36: ...DDLE 80ms Auto power off Enabled Auto power off time duration 60min Bluetooth wait settings when disconnected Enabled Disconnect by hold down pairing button Wait host Sound the buzzer when reading RFI...

Page 37: ...vertical and horizontal Power save Disabled Double reading Disabled Write verify No verify Link profile 1 Link profile 4 2 1 Link profile Link profile 1 Tari 25us Tag response Miller 4 Link Frequency...

Page 38: ...Operating temperature range 20 to 40 C 4 Charging temperature range 0 to 40 C 18 to 25 C recommended Operating humidity range 5 to 95 RH 5 Storage temperature range 20 to 60 C Storage humidity range 5...

Page 39: ...26 5 Sharp temperature change dewing or freezing not allowed wet bulb temperature 30 C max 6 This is a test value obtained under room temperature conditions It is not a guaranteed value...

Page 40: ...0 926 4W EIRP or less Israel 915 917 2W EIRP or less Taiwan 922 928 4W EIRP or less Thailand 920 925 4W EIRP or less Hong Kong 920 925 4W EIRP or less Singapore 920 925 2W ERP or less Indonesia 920 92...

Page 41: ...ormance may decline at places near metals 2 RF tag performance The reading performance is a value when the measurement is implemented under the following condition Temperature 25 5 RF tag to be used D...

Page 42: ...n reading RF tag Available writing range becomes approximately a quarter to a half of the available reading range 4 Others 1 Data writing in RF tag may be impossible depending on the RF tag type and t...

Page 43: ...e Bluetooth Device Name This is a user friendly name for the Bluetooth device to identify itself Bluetooth Wireless Link Wireless communications line connecting the master and slave devices When the B...

Page 44: ...12V DC Operating temperature 0 40 Storage temprature 10 60 2 Charging time Charging SP1 BT 180LA approx 3 5 hours BT SP1L approx 7 hours Charging spare battery BT 180LA approx 4 hours BT SP1L approx...

Page 45: ...RF Tag Handy Scanner SP1 QUBi User s Manual 2nd Edition January 2020...

Reviews: