26
(3) Error rate measurement mode
Press the
8
or
9
button to select [YY] .
Refer to [Table 2 - Error rate details].
FL Display (The display part of 16 digits)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
T Y Y F F F F F F F F F F
(X : measurement mode, F : Address and error rate (When not set, "F" is displayed.)
Press the
1
button to begin error rate measurement. The address and error rate are displayed.
For a description of the displayed measurement results, see "Table 2: Error rate details".
FL Display (The display part of 16 digits)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
T Y Y m m m m m m | | | |
(YY : selection mode [71 to 94], m : address [PBA][HEX], l : error rate [COUNT/SEC] [HEX])
(Note) CD (4x-speed) : Renewal of data is carried out for every 300 frame.
Error rate of 75 frames is displayed.
DVD (2x-speed) : Renewal of data is carried out for every 80ECC block.
Error rate of 8ECC block is displayed.
BD
(2x-speed) : Renewal of data is carried out for every 136LDC clusters block.
Error rate of 8LDC clusters block is displayed.
The mode chosen when selection mode was changed into the trace execution and the
1
button was pushed is
performed from the beginning.
When the
1
button is pushed without changing selection mode, the mode under selection is performed from the
beginning.
(If the
1
button is pushed, the address corresponding to the chosen mode will be searched again.)
The pause mode is set after tracing is completed.
When the
2
button is pressed, the layer above the current layer is displayed. See "5.4 Stopping the mode".
(4) Accumulated laser on time display mode
Press the
8
or
9
button to select [Y] and press the
1
button to set it.
The accumulated laser on time is displayed.
FL Display (The display part of 16 digits)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
T C Y
m m m m m m h
(Y=1 : CD, 2 : DVD , 3 : BD, mmmmmm : Time(Fractions of hours are counted up one hour on the display.)
When the
2
button is pressed, the layer above the current layer is displayed. See "5.4 Stopping the mode".
---To clear the accumulated laser on time---
Press the
1
button while the accumulated laser on time is displayed ("TC1, "TC2", "TC3" ) until "
*
" appears at
the fourth position.
FL Display (The display part of 16 digits)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
T C Y *
m m m m m m
Press the
8
or
9
button to select "TC4"
FL Display (The display part of 16 digits)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
T C 4 *
If the
1
button is pressed while "TC4" is displayed, the accumulated laser on time of CD, DVD and BD is cleared.
FL Display (The display part of 16 digits)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
T C 1
0 0 0 0 0 0 h
When "TC1", "TC2" or "TC3" is selected with the
8
or
9
button, "mmmmmm" is displayed as "0" so you can
check.
Summary of Contents for S-5BD
Page 54: ...54 ANALOG VIDEO OUTPUT SIGNAL Signal Color Bar 100 Composite S5BD Oscilloscope 75ohm Loard...
Page 135: ...135 ADAU1328BSTZ 8U 310035 IC103 66 AVR 2310CI 2310 890 AVC 2310 ADAU1328 IC301 HDMI B D...
Page 147: ...147 2 FL DISPLAY FLD 19 ST 02GINK FL851 PIN CONNECTION GRID ASSIGNMENT...
Page 148: ...148 ANODE CONNECTION...