Part names and
Functions
Connections
Playback
Selecting
Files and
Folders
Getting Started
Control
Function
Information
23
Selecting
Media
Recording
Edit Function
Setting defaults
Setting defaults
Setting Items
Setting details (Items in bold are factory default)
27 IP Control Port
z
2
0 to 65535 (
23
): Sets the IP control port number. Please note that port
numbers 'xx' and 'xx' are not available as they are
reserved for Web Remote and DLNA.
28 IP Control Auth
z
2
Off:
Password authentication is not required for IP control.
On: Password authentication is required for IP control.
29 Network Standby
Off: Only Front Sub u-Con operates (low power operation).
On
: Power is supplied to the network related circuits even in standby
mode, and the unit can be controlled from the network.
30 NTP
Off
: NTP is not used.
On: NTP is used. Displays the NTP server address. Press
ENTER
to enter
the address. Then select the cycle of NTP.
31 Syslog
Off
: Event information is not sent to the server.
On: Event information is sent to the server. The Syslog server address is
displayed. Press
ENTER
to enter the address.
32 Time Zone
Set the offset time in
15-minute units.
–12:00 – +14:00 (
00:00
)
33 Daylight Saving
Sets daylight saving time.
Off
: Daylight saving time is not applied.
On: Daylight saving time is applied. Set the start and end date of daylight
saving time and the offset time of up to six hours in 15-minute
increments.
34 Admin Passwd
Sets the Admin Password
for when “Web Remote”,
“IP Control” or “System
Setting” are used.
****: Set the password between 6 to 12 characters.
For details on how to input the password, see “Renaming presets”
(
v
page 21).
35 Operator Passwd
Sets the Operator Password
for when “Web Remote” or
“IP Control” are used.
****: Set the password between 6 to 12 characters.
For details on how to input the password, see “Renaming presets”
(
v
page 21).
Setting Items
Setting details (Items in bold are factory default)
36 Observer Passwd
Sets the Observer Password
for when “Web Remote” or
“IP Control” are used.
****: Set the password between 6 to 12 characters.
For details on how to input the password, see “Renaming presets”
(
v
page 21).
37 PrdMgr Detect
On:
Permits connection from Product Manager.
Off: Does not permit connection from Product Manager.
NOTE
When set to off, connection cannot be made from DMR of DLNA.
38 PrdMgr Power Ctrl
On
: Permits the unit power to be switched on/off from Product Manager.
Off: Does not permit the unit power to be switched on/off from Product
Manager.
39 Auto Reboot
Off
: Does not automatically reboot.
On: Reboots automatically if the main processor freezes.
40 Default
Resets all of the system settings to the defaults.
z
2 The DN-700R will automatically reboot (power off and then back on) to enable the settings.