Warnings
Battery
• Inspect battery pack prior to use.
• Do not dismantle, puncture, crush, or incinerate.
• If the battery pack is dropped or receives a mechanical impact, ensure that the casing is not cracked or damaged.
• Do not use damaged battery packs.
• The electrolyte contained within the lithium cells can cause irritation to the respiratory tract, eyes and skin. In
addition, cell venting could result in air contaminants, including corrosive or flammable vapors. All precautions
should be taken to limit exposure to the electrolyte vapor.
Lamp Head
• Turn the lamp head off when not in use. The lamp housing can get hot.
• Do not use the lamp if ambient temperatures exceed 30°C (86°F).
• When lamp is in use, always keep the front of the light at least 6 inches from skin and any surface being illuminated.
• Avoid shining the lamp into patient’s eyes.
• Do not allow contact of the lamp to the patient.
• Use a curing filter when working with any light-curable resins.
Charging
• When charging the battery pack, inspect the charging lights to ensure that charging is active.
• Do not simultaneously touch the charging unit (when plugged in) and the patient.
• Supplied Li-ion batteries can be dangerous and even explode if improperly charged. The battery pack is designed
to be charged only by the supplied charging accessories.
• Do not position the battery charger so it is difficult to disconnect the power adapter from the wall.
General
• Check all components for burrs, nicks, and sharp edges prior to use.
• If unit is jarred or dropped, re-inspect prior to use.
• Do not use the PeriOptix headlight system or charge the battery in an oxygen-rich environment.
• Do not store liquids above the charger, battery pack or any other PeriOptix component or accessory.
• If a spill occurs to the charger, battery, lamp head or battery pack, discontinue use. Using the charger after liquid is
spilled into the unit could result in electrical shock.
• Clean only as directed.
• Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should
be used no closer than 30 cm (12 inches) to any part of the PeriOptix system, including cables specified by the
manufacturer. Otherwise, degradation of the performance of this equipment could result.
• Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this
equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this
equipment and result in improper operation.
• Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in
improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify
that they are operating normally.
• Removing the power adapter from the wall outlet is the means of isolating the headlight from the supply means.
• Compliance with radiated emissions and immunity Standards: Complies with RF Emissions test per CISPR 11
Group 1 Class B; and Immunity test per IEC 60601 test level for ESD, EFT, Surge, Power Frequency, Voltage,
Conducted RF and Radiated RF.
NOTICE: Any serious incident that has occurred in relation to the device should be reported to the manufacturer and
the competent authority of the Member State in which the user and/or patient is established.
Warranty
DenMat warrants its products to be free of original defects in material and workmanship and to perform in accordance
with specifications.
One-Year Limited Warranty
All components of headlight and battery pack system.
Warranty Exclusions:
• Breakage or failure due to tampering, misuse, neglect, accidents, modification or shipping.
• If the product is not used in accordance with manufacturer’s recommendations or instructions.
• If repaired or serviced by other than DenMat technician.
Prompt inspection and reporting of missing or damaged product should be reported to shipping carrier and DenMat
within 3 days of receipt of product.
If DenMat products or any component thereof are found to be defective or at variance with the product or
component(s) it will be replaced at no cost to the purchaser. This warranty only applies to products purchased new
from DenMat or its authorized distributors.
For any questions or problems, please contact your local distributor or call DenMat Customer Care at 800-433-6628
between the hours of 5am to 5pm (Pacific Time) Monday-Friday. Outside the U.S., please call 1-805-347-7990 or
visit denmat.com
„MicroLine
™™
Mini“ galvos lempos
sistemos ir „LumiPro
®®
“
galvos
lempos sistemos instrukcijos
Galvos lempų sistemos
Naudojimo instrukcijos