PUMP REASSEMBLY INSTRUCTIONS
18
SHAFT SEAL REPLACEMENT
See illustration
Remove worn or damaged seal from retainer. Clean gasket sealant
from retainer.
Install new seal by applying gasket sealant to retainer and pressing seal in retainer.
SEAL KITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
P07
S22-15646-0
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P110
S22-15647-0
The shaft seal and all "O" rings necessary for total seal replacement may be obtained
by ordering the Seal Kit . These seals are suitable for petroleum base fluids. For fire resistant fluids contact
DENISON
HYDRAULICS
, Inc. or their authorized distributors to obtain the appropriate
seal kit number.
SHAFT ASSEMBLIES
(see parts list, item (1) on page 13)
The following assemblies include shaft, key when applicable, bearing and seal:
P07-SAE #
P110-ISO #
Keyed, no rear drive assembly
S22-15337
S22-15598
Keyed, with rear drive assembly
S22-16027
S22-16028
Splined, no rear drive assembly
S22-15338
S22-15599
Splined, with rear drive assembly
S22-16025
S22-16026
P110-DIN #
Keyed, no rear drive assembly
S22-15673
Keyed, with rear drive assembly
S22-16030
Splined, no rear drive assembly
S22-15602
Splined, with rear drive assembly
S22-16029
PRE-ASSEMBLY
Depending on the repairs, many steps in this section may not be applicable.
The assembly area should be clean and the environment such that foreign matter will not be introduced to the pump
during assembly. All parts must be absolutely clean and free from rust, contamination, lint, or any other foreign matter.
Critical surfaces must be free of dings or scratches. All "O" rings and seals must be clean and carefully examined for
cuts or other damage before installation.
During assembly, occasional reference will be made to the use of lubricating oil for proper assembly. It is important
that any oil used be compatible with the seals and fluid to be used in operation. Compatibility is also necessary for
grease which should be used on all "O" rings to ensure proper assembly without damage.
THREAD LOCKING AND SEALANT
Several screws require a thread locking compound for locking in position. When thread locking compound is required
use Loctite® #242 or equivalent. Where hydraulic sealant is specified, use Loctite® Hydraulic Sealant or equivalent.
Where gasket sealant is specified, use Loctite® Master Gasket or equivalent.
ASSEMBLY
Refer to illustration, see figure 1. See page 26 for tightening torque on plugs
1. Place the port block end of the housing (7) on a suitable surface capable of supporting the pump weight of 177 lbs,
80,3 Kgs.
2. Install plugs (41) with "O" rings into port block. Install plugs (32) with "O" rings into port block.
3. Install pin (16) in port block. Position port plate (14) on port block and over pin. To view correct port plate for shaft
rotation specified.
See illustration, below
Port Plate for CW Shaft Rotation
(Ref. Barrel and Port Plate Assembly S22-16
145
)
Port Plate for CCW Shaft Rotation
(Ref. Barrel and Port Plate Assembly S22-16
146
)
SLOT FOR PORT
BLOCK LOCATING PIN
www.comoso.com
Summary of Contents for P07 C-mod
Page 54: ...PQ HIGH RESPONSE CONTROL 54 PQ CONTROL IN PROCESS OF DEVELOPMENT www comoso com ...
Page 55: ...PQ HIGH RESPONSE CONTROL 55 PQ CONTROL IN PROCESS OF DEVELOPMENT www comoso com ...
Page 56: ...PQ HIGH RESPONSE CONTROL 56 PQ CONTROL IN PROCESS OF DEVELOPMENT www comoso com ...
Page 57: ...PQ HIGH RESPONSE CONTROL 57 PQ CONTROL IN PROCESS OF DEVELOPMENT www comoso com ...
Page 74: ...74 TEST PROCEDURE PQ CONTROL IN PROCESS OF DEVELOPMENT www comoso com ...