Denios 160416W User Manual Download Page 9

 

 

 

 

bio.x T700 160416 

Page 9 of 16 

10/2008 

Energy-saving mode 

The unit can be switched to energy-saving mode during downtimes such as night-time, weekends, or company 
holidays.  To do so, the multi-function button is pressed for 3 seconds.  "30" will be shown on the display. The 
temperature is maintained at 30º C in energy-saving mode.  The micro-organisms remain active at this 
temperature and optimum oil and grease degradation is guaranteed.   
You can switch from energy-saving mode by just pressing the button again and the unit will heat the detergent to 
41º C again.  The warm-up stage takes about an hour, depending on the ambient temperature. Once this 
temperature is reached and "41" is shown continuously on the display, the unit is ready for operation with optimum 
cleaning assured.  

 

8. Maintenance  

 

Warning!

  Before starting work on the cleaning table fixtures, switch off the electrics and unplug from 

the mains! Test the equipment to ensure the power is off! 

8.1 Filter 

The washstand is equipped with two filters as standard. A stainless steel perforated filter on the washstand surface 
and a synthetic filter for impurities underneath.  It is recommended to clean these filters on a 

daily

 basis. To do so, 

remove the filters from the unit and rinse with water.  

 

 

For maintenance purposes the work surface can be lifted 
inside the tank and lent against the back wall of the upper 
part.

.

 

 

8.2 Fill level 

Check the fill level against the markings on the tank wall regularly 
so you can refill to make up for any losses through evaporation 
and removal.  If the fill level falls under a minimum of 60 litres 
(lowest marker line), the pump and the heating system switch off 
automatically for safety reasons. In such a case, "LO" is shown on the display.  Re-fill the detergent until the top 
marker line is reached.  The message will disappear once there is enough detergent in the tank.  
 

8.3Additive 

More additive should be put in every 6 months to replenish the micro-organisms.  
After refilling, the detergent must be left to stand for 24 hours so that the micro-organisms can become 
active.  It is therefore recommended to refill with the additive before a weekend.  

 

8.4Suction filter (6) 

In order to prevent the pump from losing pressure, the suction filter inside the tank should be cleaned at regular 
intervals. For this purpose the suction filter can be moved to an elevated position and with the help of the cleaning 
nozzle (set to surface jet) freed from deposits. 
If the suction filter is so dirty that it can no longer be cleaned in this way, it has to be replaced. 
 

Perforated filter 

Summary of Contents for 160416W

Page 1: ...Cleaning Table USERS MANUAL 10 2008 Mat Nr 162518_BA_EN_004...

Page 2: ...bio x T700 160416 Page 2 of 16 10 2008...

Page 3: ...the cleaning fluid 7 6 Bedienfeld 8 6 1 Function indicators on the display 8 7 Operation 8 8 Maintenance 9 8 1 Filter 9 8 2 Fill level 9 8 3Additive 9 8 4Suction filter 6 9 8 5 Cleaning fluid 10 8 6 F...

Page 4: ...prohibitions and hazard warnings The mains supply connection has to be in accordance with the corresponding regulations VDE 01000 Association of German Electricians For safety reasons the equipment m...

Page 5: ...4 l min 160253 8 Foot switch button optional For turning the cleaning function and the demister on and off 150097 9 On off button For turning the internal light on off optional 162245 10 Feed cable w...

Page 6: ...bio x T700 160416 Page 6 of 16 10 2008 1 13 10 24 9 23 16 12 21 26 27 24 8 15 19 20 25 18 17 16 22 6 3 6 Cleaning position Operating position 2 5 4 7 11...

Page 7: ...n on the display for 3 seconds The heating system switches on automatically The warming up process can take up to 2 5 hours depending on the initial temperature The operating temperature is set at 41...

Page 8: ...e maximum load of 200 kg Connect the Vario nozzle or the cleaning brush with the high speed coupling to the cleaning hose Close the cover If necessary turn on the light with the on off switch 9 Reach...

Page 9: ...ly basis To do so remove the filters from the unit and rinse with water For maintenance purposes the work surface can be lifted inside the tank and lent against the back wall of the upper part 8 2 Fil...

Page 10: ...seal is in the correct position 8 7Cleaning the hood Avoid scratching the hood If the hood is dusty it must under no circumstanced be rubbed dry For cleaning use a mild washing up liquid in luke warm...

Page 11: ...Perforated metal insert To protect the work surface of the cleaning table Makes it possible to work without tilting 169227 Interior lighting Protective tube light IP67 1x24W 160425 Dolly For portable...

Page 12: ...Short circuit in level switch Level switch faulty Replace level switch F 6 Detergent cold temperature sensor not working Temperature sensor not connected Connect temperature sensor F 7 Short circuit...

Page 13: ...bio x T700 160416 Page 13 of 16 10 2008 12 Connection Diagram Thermal circuit breaker Heater Pump Air pump Level Foot switch brown black blue Valve...

Page 14: ...Cleaning Table bio x complies with the following relevant provisions EC Machinery Directive 98 37 EC EC Low Voltage Directive 73 23 EC EC Electromagnetic Compatibility Directive 93 68 EC Applied harmo...

Page 15: ...bio x T700 160416 Page 15 of 16 10 2008...

Page 16: ...60416 Page 16 of 16 10 2008 DENIOS AG Dehmer Stra e 58 66 32549 Bad Oeynhausen Tel 49 0 5731 7 53 0 Fax 49 0 5731 7 53 197 E Mail info denios com You ll find your local partner on our InterNet side ww...

Reviews: