11. Faults 

 
Warning!

 Before starting work on the cleaning table fixtures, switch off the electrics and unplug from the mains Test 

the equipment to ensure the power is off  

 

Display 
screen 

Fault  

Cause  

Solution 

 

 

Detergent cold, heating system not 
working 

Heating system plug 
contacts are loose 

Check plug contacts to 
ensure connected properly. 

F 1 

Detergent cold, heating system not 
working 

1. The pump is not connected 

or is faulty;  

2. Fuse  faulty 
3. Temperature  limiter  has 

been triggered 

1. Connect heating system; 

replace if necessary  

2. Replace  fuse. 
3. Have unit checked, 

temperature limiter must be 
activated  

F 2 

Wash pump not working 

1. The pump is not connected 

or is faulty;  

2. Fuse  faulty 

1. Connect wash pump; 

replace if necessary 

2. Replace fuse.  

F 3 

Aerator not working 

1. Aerator is not connected, or 

is faulty;  

2. Fuse  faulty 

1. Connect aerator; replace if 

necessary 

2. Replace  fuse. 

F 4 

Level switch not working 

Level switch not connected 

Connect level switch 

F 5 

Short-circuit in level switch 

Level switch faulty 

Replace level switch 

F 6 

Detergent cold, temperature 
sensor not working 

Temperature sensor not 
connected 

Connect temperature 
sensor 

F 7 

Short circuit in temperature sensor

Temperature sensor faulty  

Replace temperature 
sensor 

F 8 

Demister not working 

Magnetic valve not connected 

or faulty  

 Check connection. Replace 

valve if necessary  

LO 

Heating system and wash pump 
not working 

1. Fill level fallen below 

minimum level  

2. Float switch dirty and in the 

wrong position 

1. Refill with detergent 
 
2. Clean the float-switch 

mechanism 

Overheating 

If the maximum permitted temperature (41°C) is exceeded, the current temperature will be shown as a flashing 
warning message on the display. If such a case arises, switch off the parts cleaner immediately.  Then check the 
temperature sensor PT 100 is in the correct position (3).  
The equipment is fitted with a temperature limiter to prevent damage from overheating. This switches the heating 
system off if the maximum temperature is exceeded.  
If overheating is not caused by the temperature sensor being in the wrong position, a service technician must be 
called in to find the cause and make necessary repairs. 

 

Summary of Contents for 160416W

Page 1: ...Cleaning Table USERS MANUAL 10 2008 Mat Nr 162518_BA_EN_004...

Page 2: ...bio x T700 160416 Page 2 of 16 10 2008...

Page 3: ...the cleaning fluid 7 6 Bedienfeld 8 6 1 Function indicators on the display 8 7 Operation 8 8 Maintenance 9 8 1 Filter 9 8 2 Fill level 9 8 3Additive 9 8 4Suction filter 6 9 8 5 Cleaning fluid 10 8 6 F...

Page 4: ...prohibitions and hazard warnings The mains supply connection has to be in accordance with the corresponding regulations VDE 01000 Association of German Electricians For safety reasons the equipment m...

Page 5: ...4 l min 160253 8 Foot switch button optional For turning the cleaning function and the demister on and off 150097 9 On off button For turning the internal light on off optional 162245 10 Feed cable w...

Page 6: ...bio x T700 160416 Page 6 of 16 10 2008 1 13 10 24 9 23 16 12 21 26 27 24 8 15 19 20 25 18 17 16 22 6 3 6 Cleaning position Operating position 2 5 4 7 11...

Page 7: ...n on the display for 3 seconds The heating system switches on automatically The warming up process can take up to 2 5 hours depending on the initial temperature The operating temperature is set at 41...

Page 8: ...e maximum load of 200 kg Connect the Vario nozzle or the cleaning brush with the high speed coupling to the cleaning hose Close the cover If necessary turn on the light with the on off switch 9 Reach...

Page 9: ...ly basis To do so remove the filters from the unit and rinse with water For maintenance purposes the work surface can be lifted inside the tank and lent against the back wall of the upper part 8 2 Fil...

Page 10: ...seal is in the correct position 8 7Cleaning the hood Avoid scratching the hood If the hood is dusty it must under no circumstanced be rubbed dry For cleaning use a mild washing up liquid in luke warm...

Page 11: ...Perforated metal insert To protect the work surface of the cleaning table Makes it possible to work without tilting 169227 Interior lighting Protective tube light IP67 1x24W 160425 Dolly For portable...

Page 12: ...Short circuit in level switch Level switch faulty Replace level switch F 6 Detergent cold temperature sensor not working Temperature sensor not connected Connect temperature sensor F 7 Short circuit...

Page 13: ...bio x T700 160416 Page 13 of 16 10 2008 12 Connection Diagram Thermal circuit breaker Heater Pump Air pump Level Foot switch brown black blue Valve...

Page 14: ...Cleaning Table bio x complies with the following relevant provisions EC Machinery Directive 98 37 EC EC Low Voltage Directive 73 23 EC EC Electromagnetic Compatibility Directive 93 68 EC Applied harmo...

Page 15: ...bio x T700 160416 Page 15 of 16 10 2008...

Page 16: ...60416 Page 16 of 16 10 2008 DENIOS AG Dehmer Stra e 58 66 32549 Bad Oeynhausen Tel 49 0 5731 7 53 0 Fax 49 0 5731 7 53 197 E Mail info denios com You ll find your local partner on our InterNet side ww...

Reviews: