Denios 160416W User Manual Download Page 5

 

 

 

 

bio.x T700 160416 

Page 5 of 16 

10/2008 

4. Product description 

4.1 Intended use 
The bio.x parts cleaning unit is used to clean oil and grease from work pieces in an efficient, environmentally 
sustainable way using exclusively cleaning fluids authorised by DENIOS.  

Other detergents such as degreasers or alkali cleaning agents must 

not

 be used! 

Solvents, disinfectants, alkali or acidic fluids, carburettor and diesel fuels or turpentine must not be poured 
into the appliance. 

4.2 Layout 
Lower part 

Material PE 

Maximum fill capacity 

120l 

Minimum fill capacity 

60l  

Item 

Description 

Function or description 

Mat. No. 

1  Electrical compact control  

With on/off switch and 2-digit 7-segment display 

169682 

2  Heating element, output 1kW 

Version with central connection and firmly sealed cable 3x1.5mm² 

178986 

3  PT 100 temperature sensor  

Temperature control (41°C) 

135266 

4  Level switch  

Recording the minimum fill level, plastic version with firmly sealed 
PVC cable 3x0.34mm² 

135274 

5  Electrical aerator (5W) 

Oxygen supply for the bacteria in the cleaning device 

138281 

6  Suction filter (350µm)  

Protection against contamination in the feed pump inlet 

168159 

Feed pump,  
temperature monitored * 

Three-compartment membrane pump which can run dry safely, 
operating pressure approx. 6bar, flow rate 4 l/min 

160253 

8  Foot switch/button (optional) 

For turning the cleaning function and the demister on and off  

150097 

9  On/off button  

For turning the internal light on/off (optional) 

162245 

10  Feed cable with plug 

 

160517 

11  Drain tap 

To drain the used cleaning fluid 

162221 

* When replacing the connections of the hose feed, seal with a Teflon band 
Upper part 

Material PE 

to be placed on the lower part of the appliance 

with back and side walls and a removable work surface 

Load capacity: 200 kg 

Usable work surface: 750x900x550 mm 

Item Description 

Function or description 

Mat. No. 

12 

Filter screen (600µm) 

For filtering out coarse particles 

135256 

13 

Interior lighting (optional) 

Protective tube light IP67, 1x24W 

172777 

15 

Lamella protective plate 

Stainless steel, to cover the ventilation opening 

162335 

16 

Pressure hose 

Feed to the Vario nozzle, cut 1100 mm 

162495 

17 

Vario nozzle 

Can be adjusted from point to surface jet and unpressurised 

168143 

18 

Wash brush 

For manual cleaning  

168024  

19 

Compressed-air nozzle (optional)  For fast drying of the cleaned workpieces 

168250 

20 

Holder 

To hold the nozzles and the brush 

168767 

21 

Work surface (fold-away shelf) 

In blue 

161846 

22 

SET: Vario nozzle and wash 

brush with hose system 

 

162496 

23 

Nozzle for demister 

To blow clean the hood 

163366 

Hood 

Material: transparent thermoplastic 

surrounding seal, lock and reach-through gauntlets 

Item Description 

Mat. 

No. 

24 Hood 

162349 

25 Reach-through 

gauntlet 

168036 

26 Lock 

160262 

27 Seal 

162482 

 
 

Summary of Contents for 160416W

Page 1: ...Cleaning Table USERS MANUAL 10 2008 Mat Nr 162518_BA_EN_004...

Page 2: ...bio x T700 160416 Page 2 of 16 10 2008...

Page 3: ...the cleaning fluid 7 6 Bedienfeld 8 6 1 Function indicators on the display 8 7 Operation 8 8 Maintenance 9 8 1 Filter 9 8 2 Fill level 9 8 3Additive 9 8 4Suction filter 6 9 8 5 Cleaning fluid 10 8 6 F...

Page 4: ...prohibitions and hazard warnings The mains supply connection has to be in accordance with the corresponding regulations VDE 01000 Association of German Electricians For safety reasons the equipment m...

Page 5: ...4 l min 160253 8 Foot switch button optional For turning the cleaning function and the demister on and off 150097 9 On off button For turning the internal light on off optional 162245 10 Feed cable w...

Page 6: ...bio x T700 160416 Page 6 of 16 10 2008 1 13 10 24 9 23 16 12 21 26 27 24 8 15 19 20 25 18 17 16 22 6 3 6 Cleaning position Operating position 2 5 4 7 11...

Page 7: ...n on the display for 3 seconds The heating system switches on automatically The warming up process can take up to 2 5 hours depending on the initial temperature The operating temperature is set at 41...

Page 8: ...e maximum load of 200 kg Connect the Vario nozzle or the cleaning brush with the high speed coupling to the cleaning hose Close the cover If necessary turn on the light with the on off switch 9 Reach...

Page 9: ...ly basis To do so remove the filters from the unit and rinse with water For maintenance purposes the work surface can be lifted inside the tank and lent against the back wall of the upper part 8 2 Fil...

Page 10: ...seal is in the correct position 8 7Cleaning the hood Avoid scratching the hood If the hood is dusty it must under no circumstanced be rubbed dry For cleaning use a mild washing up liquid in luke warm...

Page 11: ...Perforated metal insert To protect the work surface of the cleaning table Makes it possible to work without tilting 169227 Interior lighting Protective tube light IP67 1x24W 160425 Dolly For portable...

Page 12: ...Short circuit in level switch Level switch faulty Replace level switch F 6 Detergent cold temperature sensor not working Temperature sensor not connected Connect temperature sensor F 7 Short circuit...

Page 13: ...bio x T700 160416 Page 13 of 16 10 2008 12 Connection Diagram Thermal circuit breaker Heater Pump Air pump Level Foot switch brown black blue Valve...

Page 14: ...Cleaning Table bio x complies with the following relevant provisions EC Machinery Directive 98 37 EC EC Low Voltage Directive 73 23 EC EC Electromagnetic Compatibility Directive 93 68 EC Applied harmo...

Page 15: ...bio x T700 160416 Page 15 of 16 10 2008...

Page 16: ...60416 Page 16 of 16 10 2008 DENIOS AG Dehmer Stra e 58 66 32549 Bad Oeynhausen Tel 49 0 5731 7 53 0 Fax 49 0 5731 7 53 197 E Mail info denios com You ll find your local partner on our InterNet side ww...

Reviews: