5. Initial Operation
After removing the packaging, check the unit casing and operating components for any possible damage caused in
transit. If such damage is found, do not connect the unit to the mains. Report damage immediately to the carrier
who delivered the unit and to DENIOS AG at the service number indicated above. The original packaging should
be kept.
Place the unit in a dry, stable location as required. The floor must be level. If necessary, level out any uneven
surfaces with suitable shimming material.
5.1 Electrical connection
The unit is connected to the customer's mains supply via the power cable and plug.
Mains voltage:
The voltage of the power source has to comply with the details on the identification place of the
appliance
Warning: The mains supply must be fitted with a residual current protective device in accordance with DIN
VDE (Association of German Electricians) 0100! (See section 2)
5.2 Filling with the cleaning fluid
Open the hood (24) and take out the shelf (21) from the unit.
Two different cleaning fluids can be used in the Part Cleaning Unit T700.
a) Bio-Power
cleaning
fluid
•
Pour 100 l (5 canisters) of Bio-Power cleaning fluid into the tank.
•
Connect the unit to the mains. "On" will be shown on the display for 3 seconds. The heating system switches on
automatically. The warming-up process can take up to 2.5 hours, depending on the initial temperature. The
operating temperature is set at 41º C in the factory and cannot be changed. When the operating temperature is
reached, "41" will appear on the display.
The aerator will work continuously after the unit is switched on.
•
Once the operating temperature is reached add the additive with the micro-organisms (1 can x 100 g) to the
fluid. The micro-organisms take 24 hours to become active. It is therefore recommended to set up the unit for
operation just before the weekend, for instance.
The parts cleaning unit is then ready for operation.
b) Cleaning fluid bio.x (ready-for-use solution incl. micro-organisms)
•
Pour 100 l (5 canisters) of Cleaning fluid bio.x into the tank.
•
Connect the unit to the mains. "On" will be shown on the display for 3 seconds. The heating system switches
on automatically. The warming-up process can take up to 2.5 hours, depending on the initial temperature. The
operating temperature is set at 41º C in the factory and cannot be changed. When the operating temperature
is reached, "41" will appear on the display.
The parts cleaning unit is then ready for operation.
The aerator will work continuously after the unit is switched on.
The two detergents should not be mixed together as far as this is possible.
Other detergents such as degreasers or alkali cleaning agents must not be used.