Cleaning Table
USERS MANUAL
10/2008
Mat.-Nr. 162518_BA_EN_004
Page 1: ...Cleaning Table USERS MANUAL 10 2008 Mat Nr 162518_BA_EN_004...
Page 2: ...bio x T700 160416 Page 2 of 16 10 2008...
Page 3: ...the cleaning fluid 7 6 Bedienfeld 8 6 1 Function indicators on the display 8 7 Operation 8 8 Maintenance 9 8 1 Filter 9 8 2 Fill level 9 8 3Additive 9 8 4Suction filter 6 9 8 5 Cleaning fluid 10 8 6 F...
Page 4: ...prohibitions and hazard warnings The mains supply connection has to be in accordance with the corresponding regulations VDE 01000 Association of German Electricians For safety reasons the equipment m...
Page 5: ...4 l min 160253 8 Foot switch button optional For turning the cleaning function and the demister on and off 150097 9 On off button For turning the internal light on off optional 162245 10 Feed cable w...
Page 6: ...bio x T700 160416 Page 6 of 16 10 2008 1 13 10 24 9 23 16 12 21 26 27 24 8 15 19 20 25 18 17 16 22 6 3 6 Cleaning position Operating position 2 5 4 7 11...
Page 7: ...n on the display for 3 seconds The heating system switches on automatically The warming up process can take up to 2 5 hours depending on the initial temperature The operating temperature is set at 41...
Page 8: ...e maximum load of 200 kg Connect the Vario nozzle or the cleaning brush with the high speed coupling to the cleaning hose Close the cover If necessary turn on the light with the on off switch 9 Reach...
Page 9: ...ly basis To do so remove the filters from the unit and rinse with water For maintenance purposes the work surface can be lifted inside the tank and lent against the back wall of the upper part 8 2 Fil...
Page 10: ...seal is in the correct position 8 7Cleaning the hood Avoid scratching the hood If the hood is dusty it must under no circumstanced be rubbed dry For cleaning use a mild washing up liquid in luke warm...
Page 11: ...Perforated metal insert To protect the work surface of the cleaning table Makes it possible to work without tilting 169227 Interior lighting Protective tube light IP67 1x24W 160425 Dolly For portable...
Page 12: ...Short circuit in level switch Level switch faulty Replace level switch F 6 Detergent cold temperature sensor not working Temperature sensor not connected Connect temperature sensor F 7 Short circuit...
Page 13: ...bio x T700 160416 Page 13 of 16 10 2008 12 Connection Diagram Thermal circuit breaker Heater Pump Air pump Level Foot switch brown black blue Valve...
Page 14: ...Cleaning Table bio x complies with the following relevant provisions EC Machinery Directive 98 37 EC EC Low Voltage Directive 73 23 EC EC Electromagnetic Compatibility Directive 93 68 EC Applied harmo...
Page 15: ...bio x T700 160416 Page 15 of 16 10 2008...
Page 16: ...60416 Page 16 of 16 10 2008 DENIOS AG Dehmer Stra e 58 66 32549 Bad Oeynhausen Tel 49 0 5731 7 53 0 Fax 49 0 5731 7 53 197 E Mail info denios com You ll find your local partner on our InterNet side ww...