②
SOC Limit
You can assign the lower limit of battery SOC. Battery will stop discharging
when its SOC
reach this limit.
③
Peak Cut Power
Peak cut power is used in peak cut mode. You can assign the peak power of home load
usage from grid. When the home load consumption exceeds this value, battery will discharge
to supply remaining power.
④
Time Settings
Time settings can be separated into BT charge time and BT discharge time.
Each setting can set 3 time intervals. These 6 time intervals cannot overlap
with each other.
When the inverter operation mode set to self-consumption or selling first mode,
time settings
is enabled. Hybrid inverter will automatically change the mode
to charge first / discharge first
in the time intervals you set and return to self-consumption / selling first mode outside the
intervals.
⑤
A change is confirmed.
*
None of the settings will change until the “Save” button is touched at the end. Caution is required.
Touch to turn off the dialog box.
⑦
Change the display to the Home screen.
・
In the Home screen, touch →
.
・
Use to switch each screen.
Operating method
⑧
Touching this button to display another page menu.
Touch the desired page to switch
the display to the desired screen.
⑥
A screen in which the desired Inverter can be selected
is displayed.
Touch the button to display the Inverter Selection dialog
box. Touch the No. of the desired Inverter.
Grid Setting can be verified.
Refer to “Grid Setting” (Page 67) for details.
Sleep time ,brightness, slideshow and language for the screen can
be set.
Refer to “Screen Setting” (Page 68) for details.
81
What Power Monitor can do