Table 6-4: Fault Message (Continued)
Message
Possible cause
Action
HW Red ADC2
1. Auxiliary power circuitry
malfunction
2. Detection circuit malfunction
1. Check the auxiliary circuitry inside
the inverter
2. Check the detection circuit inside
the inverter
HW COMM2
1. Red. CPU is idling
2. The communication connection is
disconnected
1. Check the function of reset pin and
crystal in Red. CPU
2. Check the connection between
Red. CPU and DSP
HW COMM1
1. DSP is idling
2. The communication connection is
disconnected
3. The communication circuit mal-
function
1. Check the function of reset pin and
crystal in DSP
2. Check the connection between
DSP and COMM
3. Check the communication circuit
HW Connect Fail
1. Power cables fall off inside the
inverter
2. Current feedback circuit is
defective
3. Driver circuit of inverter
malfunction
1. Check the power cables inside
the inverter
2. Check the current feedback circuit
inside the inverter
3. Check driver circuit of the inverter
Relay Test Short
1. The driver circuit for the contactor
malfunction
2. The contacts of contactor are
stuck
1. Check the driver circuit inside the
inverter
2. Replace a new contactor
Relay Test Open
1. Driver circuit for Contactor is
defective
2. Contactor coil is defective
3. The detection accuracy is not
correct for Vgrid and Vout
1. Check the driver circuit for
contactor
2. Replace contactor coil
3. Check the Vgrid and Vout voltage
detection accuracy
HW Bus OVR
1. Power BackFeed Occurred (DC
Power < AC Power)
2. Something wrong with AC
Frequency PLL
1. Check the connection between
Solar Panel and Inverter
2. Check the Vgrid and Vout voltage
detection accuracy
Summary of Contents for PhotoVoltaic RPI-C500
Page 1: ...PhotoVoltaic Inverter RPI C500 PV Inverter ...
Page 88: ...INSTALLATION GUIDE 82 ...
Page 89: ...光伏逆变器 RPI C500 光伏逆变器 ...
Page 100: ...安装手册 5 产品外观 外部三角视图 3 2 2 外部三角视图 图 3 2 外部后视图 进气孔 ...
Page 114: ...安装手册 20 安装说明 DC 端连接 图 5 4 DC 端连接端尺寸图 ...
Page 116: ...安装手册 22 安装说明 AC 端连接 5 3 AC 端连接 1 如图 5 6 所示将连接到 AC 端的电缆穿过底板 图 5 6 AC 端配线 ...
Page 119: ...安装手册 25 安装说明 AC 端连接 图 5 9 AC 端连接端尺寸图 ...
Page 156: ...安装手册 62 维修保养 更换风扇模块 7 维修保养 7 1 更换风扇模块 1 按拉且扭转把手 之后打开后门 图 7 1 按拉扭转把手 ...
Page 158: ...安装手册 64 维修保养 更换风扇模块 4 松开锁附在上风扇与机壳上的螺丝 然后将上风扇移除 图 7 4 松开上风扇的螺丝 ...
Page 160: ...安装手册 66 维修保养 更换进气口滤网 3 松开锁附在滤网上的螺丝 图 7 7 松开滤网的螺丝 4 取出滤网 图 7 8 取出滤网 ...
Page 162: ...安装手册 68 维修保养 清理排气孔滤网 4 直接取出挡板和排气孔滤网 图 7 11 取出排气孔滤网 ...
Page 165: ...安装手册 71 维修保养 更换 SURGE PROTECTION DEVICE 4 退出已损坏的 SPD 并更换新的 Figure 7 15 退出已损坏的 SPD ...
Page 176: ...Version 01180521 5013209808 ...