Chapter 3 Introduction to Functions
3-29
_3
Description
Default
serial servers can be configured. Ports default are 4001
~ 4004 and configurable
Designated local port
Set up the local port for the each connection
14001~14004
Packing length
Set up the threshold for sending packets. Range from 0
to 1024 bytes. 0 means it is immediately sent once data
coming.
0
Force transmit
Set up the how long it will wait before it send packets
mandatory. Range from 0 to 65536 millisecond. 0
means never send packets mandatory.
0
Serial Server –
UDP Client
Destination IP address and port
Set the IP segment and port of the serial server. Up to 4
segments can be configured and there are at most 99
addresses in each segment. Port defaults are 6001 ~
6004 and configurable.
Local listen port
Set up the local port.
15000
Packing length
Set up the threshold for sending packets. Range from 0
to 1024 bytes. 0 means it is immediately sent once data
coming.
0
Force transmit
Set up the how long it will wait before it send packets
mandatory. Range from 0 to 65536 millisecond. 0
means never send packets mandatory.
0
3.4.5
Modbus TCP
This page is used for configuring the Modbus TCP, including Working Mode, Server IP, Server Port, and Response
Timeout.
Summary of Contents for DX-3001 Series
Page 21: ...Chapter 2 Introduction to User Interface 2 9 2_ 4 Cellular setting page ...
Page 44: ...Chapter 3 Introduction to Functions 3 19 _3 ...
Page 45: ...DX 3001 Series Industrial Cloud Router 3 20 _3 ...
Page 49: ...DX 3001 Series Industrial Cloud Router 3 24 _3 ...
Page 50: ...Chapter 3 Introduction to Functions 3 25 _3 ...
Page 115: ...CH5 Introduction to IOT DIACloud 5 25 _5 ...
Page 123: ...DX 3001 Series Industrial Cloud Router 6 8 _6 ...