SM150T User Manual 1.0
Operation
19
The SM150T soil moisture output is best connected as a differential,
powered sensor.
Configure the logger to convert the SM150T readings from milliVolts into
soil moisture units by using either :-
below (or on page 28) or
on page 29
Note: Output signals in the range 0 to 1.0 volts from the SM150T,
corresponding to ~0 to 60% water content in mineral soils
– see
Linearisation table conversion
on page 29.
Note: The SM150T has been optimised for warm-up of 0.5 to 1 second
duration. It is recommended that the sensor is not powered continuously.
The temperature sensor output should be read as a resistance and the
logger configured with a look-up table to covert the measured resistance
to temperature.
See
SM300 Temperature Measurement
on page 50
and
Resistance to Temperature Lookup Table
on page 53.
Logging Advice
Allow 20 minutes for the temperature readings to stabilise after installation
Do not log faster than 1 minute to avoid SM300 self-heating, which could
affect the accuracy of temperature readings.
5
Tables are only available for mineral and organic soils (and temperature).