Page.38.
a. Connect the black test lead to the “COM” jack and the red test lead to the“mA” jack for a maximum
of 660mA current. For a maximum of 10A, move the red lead to the 10A jack.
b. Press to select A
~
, enter the AC current measurement. Manual range by press
only manual range supply.
Manual range
:
0.000mA
6.600mA range
00.00mA
66.00mA range
000.0mA
660.0mA range
00.00A
10.00A range
(
use 10A socket
)
c. Connect test leads in series with the load under measurement.
d. You can get reading from LCD.
NOTE:
When only the figure “OL” is displayed, it indicates over range situation and the higher range has to
be selected.
When the value scale to be measured is unknown beforehand, set the range selector at the highest
position.
The maximum current of mA socket is 660mA; over-current will destroy the fuse, and will damage
the meter.
The maximum current of 10A socket is 10A, over-current will destroy the meter, and will damage
the operator.
In“ AC” mode, only can input “AC”, if not, will damage the meter.
Resistance Measuring
a. Connect the black test lead to the “COM ” jack and the red test lead to the“V/Ω” jack.
b. Press to select Ω, enter the Ω measurement. Auto range by press key, and manual range
by press .
WARNING!
Shut down the power of the tested circuit, and then connect the meter with the circuit for
measurement.