Page.44.
Built-in BNC, network cable, RVV control cable, Telephone line can test. 12 groups user-defined cable
can be set.
Press to line type interface, press to choose the line type, press to save and
start testing.
Press to adjust the speed, if select the user-defined cable type, adjust the speed after the
calibration.
User-defined calibration
:
Choose the cable 100 meters to 200 meters (more than 50 meters) press
to set the user-defined calibration. Press to select user 1 to calibrate, 12 groups
user-defined can be set.
Press to “Adjust”, press to cable type, press to choose the cable style, press
to “Speed” and press to adjust. While display length is the same as the
actual length, press to save. It can be used for the same cable after the calibration.
Application
:
The disconnection and short circuit display in the tester, it is more convenient and efficient to repair the
faulty cable.
Note
:
The TDR reflect signal could be affected by the cable quality/ cable’s not well
connected etc to cause the different TDR measurement. The TDR measurement is for reference
only.