background image

Page.48. 

 

3.6 Audio input test 

Test the audio input from pickup devices. Connect the tester and pickup device with the audio cable.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.7 LED lamp 

With the LED lamp can work in the evening or in the dark. 

Turn on the tester, press            for several seconds, and the LED lamp turn on, press          , and turn it 

off.   

Summary of Contents for CST-706

Page 1: ...CCTV Tester Manual V2 10...

Page 2: ...ad the Safety Information carefully in the manual The manual should be kept well in case of reference Keep the S N label for after sale service within warranty period Product without S N label will be...

Page 3: ...6 Enhanced Color bar generator 6 2 3 7 DC12V 2Aoutput power 6 2 3 8 Audio testing 6 2 3 9 Cable tester 6 2 3 10 PTZ controller 6 2 3 11 Data monitor 6 2 3 12 PTZ address scanning 6 2 3 13 Image magni...

Page 4: ...wer output power bank 10 2 4 ACCESSORIES 10 2 5 FRONT PANEL 11 3 OPERATION 14 3 1 Installing the Battery 14 3 2 Instrument connection 15 3 3 OSD Menu 17 3 3 1 PTZ controller 18 3 3 2 Color bargenerato...

Page 5: ...Fault Locator optional 43 3 3 23TDR Tester optional 43 3 3 24 Data monitor 45 3 3 23 Device setting 45 3 3 25 USB 46 3 4 DC12V 2A power output 46 3 5 USB 5V 2A power output 47 3 6 Audio input test 48...

Page 6: ...mp power off immediately and move away other connected cables The tester should not be used in the environment with the flammable gas Do not disassemble the instrument since no component inside can be...

Page 7: ...switch is in the current resistance capacitance diode continuity otherwise it will damage the meter Never perform capacitance measurements unless the capacitor to be measured has been discharged fully...

Page 8: ...es it is also a magic tools to find out the correct cable from the clutter cabling system and diagnose the location of the cable s short circuit and break point This advanced tester is developed for t...

Page 9: ...onnected IP camera and other network devices POE voltage measurement test the PoE switch s voltage to IP cameras wireless AP device and other PD devices Device Port flicker easy to find the connected...

Page 10: ...hannel SDI input and 1 channel SDI output 7 inch HD LCD screen 800 RGB x 600 resolution supports HD camera in 1080P 25 30 50 60 frames and 720P 25 30 50 60frames Very convenient and useful to install...

Page 11: ...ester It is helpful for demo and testing when the power supply is not available 2 3 8 Audio testing Test the audio input from pickup devices Connect the tester and pickup device with the audio cable 2...

Page 12: ...3 18 Port flicker The tester will send special signals to make the connected POE port flicker at special frequency which will enable the installers to easily and quickly find the connected ethernet c...

Page 13: ...t Auto Manual measuring range switching relative value measurement and locking It is easy operation and professionally accurate 2 3 24 Visualfault locator optional function refer to the last page Visu...

Page 14: ...level Video signal PEAK level For PAL format the video signal level is 1000 200mV For NTSC format the video signal level is 140 15IRE If the level is too low it will cause the image to dim and reduce...

Page 15: ...le testing accurately measure BNC cable network cable control cable break point cable length and short circuits location It improves working efficiency 2 3 30 USB 5V 2A power output power bank Standar...

Page 16: ...Page 11 13 Tool bag 14 Manual 15 SD card 4G 2 5 Front Panel...

Page 17: ...irm Open LED Lamp switch key 13 Upward Select the item which will be set or add the value of the parameter Tilt the PTZ upward 14 Downward Select the item which will be set or reduce the value of the...

Page 18: ...powered on HDMI Top interface SDI Top interface Bottom interface 22 HDMI input interface SDI video input interface 23 RS232 interface RS232 communication for the PTZ SDI video output interface 24 RS4...

Page 19: ...rd 37 USB interface only for data transmission 38 Charge interface 39 VGA IN interface 40 Output DC12V2A power for provisional DC test supply 41 USB 5V 2A power output as a power bank not used for dat...

Page 20: ...when the charging is completed Note Press the RESET key at the left of the instrument to restore the default settings when the instrument works abnormally Multimeter the red and black lead pen must in...

Page 21: ...t interface connect to the Video input of monitor and optical video transmitter and receiver the image display on the tester and monitor 3 Connect the camera or the speed dome RS485 controller cable t...

Page 22: ...itch to the desired function menu Anytime press this key to enter the menu In various functional mode press the key Set the various parameter values When turn it on press the key to enter the function...

Page 23: ...ow cursor to select Press the key or change the parameter values Then press the key to save and return If no change Press the key to return setting and then press the key return the PTZ controller fun...

Page 24: ...trol After setting the parameter the tester can control the PTZ and lens Press the key to control the PTZ direction of rotation Press the key or to switch on or turn off the aperture Press the key or...

Page 25: ...y control system be used different preset position pls refer to the dome camera manual The provided dome camera enter the the menu by calling preset position 64 this example is for reference only a Pr...

Page 26: ...port Display the video input and output This feature is available for test monitoring transmission channels such as optical video transmitter and receiver video cables etc the Video out port connect...

Page 27: ...mage whether shift 3 3 3Video level meter Press to choose menu and press to enter The HD SDI tester has adopted the high speed sampling from hardware and processing technology enable it to achieve mor...

Page 28: ...ad to reduce the image s color levels and dynamic range COLOR BURST chroma level by testing the color burst level to estimate whether the coaxial cable is the best to transmit the details and color Fo...

Page 29: ...in washed out pictures with decreased 4 Depending on the type of camera connected to the CCTV tester the Video Format will automatically change between NTSC and PAL and the Video Level will automatica...

Page 30: ...Press the key to switch VGA interface press the key to select VGA press the key to enter VGA If no VGA signal input display No video input Enter VGA interface Auto identify input signal resolution If...

Page 31: ...NVR 3 3 7 HDMI signal input Press the key switch to HDMI interface press the key to select HDMI press the key to enter HDMI If no HDMI signal input display No video input If receive HDMI signal but th...

Page 32: ...to enter Note Please isolate the PTZ camera with other PTZ cameras before searching up Otherwise all the PTZ cameras in the same system will pan at the same time Press to select and then press to ent...

Page 33: ...ngle step incremental button the tester will search up the ID step by step When the ID is searched the PTZ camera will stop panning Manual search address Press or to search the address gradually the i...

Page 34: ...analog camera s video SDI and HDMI digital camera s video cannot be zoom in on the tester 3 3 11 Video record While video in press several seconds the icon is flicking on the top left means the video...

Page 35: ...to choose the image 3 3 13 Cable Scan optional Connect the cable to the UTP port or the CABLE SCAN VIDEO OUT port on the top Press to select then press to enter press to choose the audio type Turn on...

Page 36: ...r Note While receive the audio signal from the tester it will be influenced by the other signal and make some noise 3 3 14 PING Test Connect the cable to the LAN port press to select and then press to...

Page 37: ...equipment s ethernet port is working normally and the IP address is correct It s normal that the first data packet will be lost when start the PING testing 3 3 15 Cable tester Press to menu press to...

Page 38: ...ignals to make the connected PoE port flicker at special frequency which will enable the installers to easily and quickly find the connected ethernet cable This function can prevent mistakenly inserti...

Page 39: ...le to the LAN port press to select press to enter Press to SetIP press to set the local IP address the network segment and the network devices must be consistent After setting move the cursor to Start...

Page 40: ...otherwise will damage the tester 3 3 20 Digital Multi meter optional To press to select press to enter 1 Function Button Auto range Data hold Relative measuring Function select Manual rang 2 SYMBOLS...

Page 41: ...k and the red test lead to the V jack b Press to select U enter the DC voltage measurement c Auto range by press key and manual range by press d Manual range 0 000V 6 600V range 00 00V 66 00V range 00...

Page 42: ...e 10A socket c Connect test leads in series with the load under measurement d You can get reading from LCD NOTE When only the figure OL is displayed it indicates over range situation and the higher ra...

Page 43: ...s over range situation and the higher range has to be selected When the value scale to be measured is unknown beforehand set the range selector at the highest position The maximum current of mA socket...

Page 44: ...ack b Press to select enter the continuity test c Connect test leads across two point of the circuit under testing d If continuity exists i e resistance less than about 30 built in buzzer will sound e...

Page 45: ...00uF 66 00 F range 000 0uF 660 0 F range 0 000mF 6 600mF range 00 00mF 66 00mF range Note a The capacitance of a capacitor should be tested separately should not test in the installation of circuit b...

Page 46: ...ltage but it s may destroy the inner circuit Resistance Continuity Diode PTC component Protection Wrong input voltage will Auto enter protection state It only suitable for short and limit time work If...

Page 47: ...to be mW or dBm Note Pls keep the fiber connector and the dust cap be clean and clean the detector with the special alcohol Data hold While testing press to data hold the data will not change It s co...

Page 48: ...the fiber to the device s VFL interface default output power is 10mW and the wavelength is 650nm Press to adjust pulse mode and stable model 3 3 23TDR Tester optional Note The testing cable can t be c...

Page 49: ...ned calibration Press to select user 1 to calibrate 12 groups user defined can be set Press to Adjust press to cable type press to choose the cable style press to Speed and press to adjust While displ...

Page 50: ...ess to empty while the tester receives the code Though the RS485 port display the PTZ control code of the multifunctional keyboard or the DVR Controller can check the status of the RS485 transmission...

Page 51: ...enu and background 0 7 Address search off on Open or close the PTZ address search Menu Time setting Press to enter set the time and date F1 user defined keyboard shortcuts Users can set the function a...

Page 52: ...an 2A the CCTV tester will enter protection mode Disconnect all the connections of the CCTV tester and then connect the CCTV tester with power adaptor to resume the CCTV tester d Make sure the the tes...

Page 53: ...nput from pickup devices Connect the tester and pickup device with the audio cable 3 7 LED lamp With the LED lamp can work in the evening or in the dark Turn on the tester press for several seconds an...

Page 54: ...ghtness Contrast Saturation adjustable Video IN OUT 1 channel BNC Input 1 channel BNC Output VGA input display VGA Input Receive VGA signals from DVR NVR Video Level test Level test Video signals meas...

Page 55: ...evice 10x Zoom Image Image 10x zoom 10x zoom image display and video out Photograph Video record Record playback Photograph snapshot and save the current image as JPG file Video record Video record an...

Page 56: ...the measured value Relative measurement Display the relative power value Continuity testing Built in buzzer will sound if resistance is lower than 30 Testing speed 3 times seconds Data range 6600 660...

Page 57: ...uguese German French Spanish Italian Russian etc Auto off 5 60 mins Keytone On Off General WorkingTemperature 10 50 Working Humidity 30 90 Dimension Weight 256mm x 173mm x 50mm 1 2kg Note Optional 4 2...

Page 58: ...0mV 660 0V 1 6 100mV DC Current Range Accuracy Resolution 6 600mA 0 5 3 1uA 66 00mA 10uA 660 0mA 1 3 100uA 10 00A 1 5 10mA AC Current Range Accuracy Resolution 6 600mA 1 5 1uA 66 00mA 10uA 660 0mA 100...

Page 59: ...5 10K Continuity Range Resolution Function 660 0 0 1 The measurement value less 30 3 the tester will sound Diode Range Resolution Function 2 0V 1mV Schottky diode 0 15 0 25V rectifier diode 0 6 1 0V...

Page 60: ...00nF 6 600mF 1uF 66 00mF 10uF 4 3 Optical power meter specifications Measure Range dBm 70 10dBm Wavelength nm 850nm 1300nm 1310nm 1490nm 1550nm 1625nm Detector InGaAs Uncertainly 3 dB 10dBm 22 5 dB fu...

Page 61: ...W Control mode CW 1Hz 2Hz Measurement distance 5KM 10 20KM Connector type FC PC Operating Temperature 10 50 Storage Temperature 20 70 The data above is only for reference and any change of them will n...

Reviews: