![Delta OHM HD2102.1 Manual Download Page 34](http://html1.mh-extra.com/html/delta-ohm/hd2102-1/hd2102-1_manual_2478293034.webp)
ORDER
CODES
HD2102.1K
The kit is composed of the instrument HD2102.1, connection cable for serial
output HD2110CSNM, 4 1.5V alkaline batteries, operating manual, case and
DeltaLog9 software.
The probes must be ordered separately.
HD2102.2K
The kit is composed of the HD2102.2
datalogger,
connection cable
HD2101/USB, 4 1.5V alkaline batteries, operating manual, case and DeltaLog9
software.
The probes must be ordered separately.
HD2110CSNM
8-pole connection cable MiniDin - Sub D 9-pole female for RS232C.
HD2101/USB
Connection cable USB 2.0 connector type A - 8-pole MiniDin.
DeltaLog9
Software for transfer and management of the data on PC using Windows 98 to
XP operating systems.
AF209.60
Stabilized power supply at 230Vac/9Vdc-300mA mains voltage.
S'print-BT
On request, portable, serial input, 24 column thermal printer, 58mm paper width.
Probes complete with SICRAM module
LP 471 PHOT
Photometric probe for
ILLUMINANCE
measurement complete with SICRAM
module, spectral response in agreement with standard photopic vision, diffuser
for cosine correction. Measurement range: 0.01 lux…200
⋅
10
3
lux.
LP 471 LUM 2
Photometric probe for
LUMINANCE
measurement complete with SICRAM
module, spectral response in agreement with standard photopic vision, vision
angle 2°. Measurement range: 0.1 cd/m
2
…2000
⋅
10
3
cd/m
2
.
LP 471 PAR
Quantum radiometric probe for the measurement of the photon flow across the
chlorophyll range
PAR
(Photosynthetically Active Radiation 400nm…700nm)
complete with SICRAM, measurement in
μ
mol/m
2
s, diffuser for cosine
correction. Measurement range: 0.01
μ
mol/m
2
s…10
⋅
10
3
μ
mol/m
2
s
LP 471 RAD
Radiometric probe for
IRRADIANCE
measurement complete with SICRAM
module; in the 400nm…1050nm spectral range, diffuser for cosine correction.
Measurement range: 0.1
⋅
10
-3
W/m
2
…2000 W/m
2
.
LP 471 UVA
Radiometric probe for
IRRADIANCE
measurement complete with SICRAM
module; in the 315nm…400nm, peak 360nm,
UVA
spectral range, quartz
diffuser for cosine correction.
Measurement range: 0.1
⋅
10
-3
W/m
2
…2000 W/m
2
.
LP 471 UVB
Radiometric probe for
IRRADIANCE
measurement complete with SICRAM
module, in the 280nm…315nm, peak 305nm,
UVB
spectral range, quartz
diffuser for cosine correction.
Measurement range: 0.1
⋅
10
-3
W/m
2
…2000 W/m
2
.
LP 471 UVC
Radiometric probe for
IRRADIANCE
measurement complete with SICRAM
module, in the 220nm…280nm, peak 260nm,
UVC
spectral range, quartz
diffuser for cosine correction. Measurement range: 0.1
⋅
10
-3
W/m
2
…2000 W/m
2
.
LP 471 ERY
Radiometric probe for
EFFECTIVE TOTAL IRRADIANCE
(W/m
2
eff
)
according to the UV action curve (CEI EN 60335-2-27) complete with SICRAM
module. Spectral range: 250 nm…400 nm, quartz diffuser for cosine correction.
Measurement range: 0.1
⋅
10
-3
W
eff
/m
2
… 2000 W
eff
/m
2
- -
34