background image

EN

10

11

2/  Connection

3/  Stop sett ings

3.1  Stop sett ings

You can use Auto mode if there are both upper and lower physical stops. The motor 
will automatically detect its end of travel distances.
If there are no upper physical stops and/or automatic locks, you must set the end of 
travel manually. 
You can use the step by step mode to stop the shutter in the exact position you 
choose.

There are several ways to confi gure stops:

 

• 2 automatic stops,

 

• 1 manual stop and 1 automatic stop,

 

• 2 manual stops.

• There is no priority direction for the stop teaching process. 

The recording of the fi rst stop, whether high or low, will be confi rmed by a single 

movement of the motor, and the second by 2 movements.
• Match the direction of the inverter with the direction of the shutter by 
changing the inverter wires (reverse the black wire and the brown wire).
• 

IMPORTANT: 

This operation must be done before saving the fi rst stop.

The electrical wiring must comply with EN, IEC and national institute standards for 
installation (e.g.: NF C15-100 for France). 
In all cases, it must still be possible to switch off the power supply by using an 
omnipolar device in accordance with the applicable installation requirement. If 
the motor is delivered with a H05VVF power cable,  this cable cannot be placed 
outdoors, unless it is inside a UV-resistant duct.
For an outdoor use, the motor must be equipped with a RNF or RRF rubber cable 
with at least 2% carbon. Contact the sales department.

Connection a with fixed or temporary 

position reversing mechanism

- A change-over switch prohibiting the buttons   or  from being pressed 
simultaneously must be used.

- In the case where a change-over switch with temporary positions is used, the 
user must press and hold the button throughout the shutter operating time.

-  You can wire up to 3 motors on the same change-over switch for grouped controls, 
but motor stops must be adjusted separately.

3 x 0.75 mm

2

2 x 1.5 mm

2

L

L

N

N

Blue

Common (Neutral)

Brown

Phase for rotation    or  .

Black

Phase for rotation    or  .

L

Phase

N

Neutral

Black

Brown

Brown

Blue

Blue

Note: If the raise and lower 
directions are reversed, swap the 
brown and black wires ( and  on 
the change-over switch).

230 V, 50 Hz 
single-phase 
power supply

You can connect Tyxia 5630/5730 nanomodules to Tymoov hard-wired motors 
(Tyxia 5630 recommended).
Make sure they are compatible by checking that the manufacturing date code is 
greater than or equal to the following one:
Tyxia 5630: 19d10
Tyxia 5730: 19h10
the shutter travel time must also be adjusted after setting the motor stops. To do 
this, download the Tyxia 5630/5730 manual and follow the ‘Manual adjustment 
for the shutter travel time’ procedure in the ‘Additional information’ section.

Summary of Contents for TYMOOV 10F

Page 1: ...EN Tubular Motor range TYMOOV 10F 20F ...

Page 2: ...must be installed at a height of at least 1 5 m The fixed control devices must be installed in a visible area Frequently check the equipment to detect any imbalances or signs of wear or damage to cables and springs Do not use the device when repairs or adjustments are required Preliminary elements Sufficiently rigid roller shutter blades should be used When the roller shutter is closed the apron m...

Page 3: ... protected to prevent overheating If there is a thermal shutdown the motor will operate again after a time period of approximately 30 minutes To operate again for 4 minutes the performance motor must have returned to room temperature DELTADORE hereby declares that the motorised systems covered by these instructions comply with the essential requirements set out by the Machinery Directive 2006 42 E...

Page 4: ...matic stops 12 3 3 Setting 1 manual stop 1 automatic stop 13 3 4 Setting 2 manual stops 14 4 Clearing stops 15 4 1 By wiring 15 4 2 By the inverter 2 options 15 5 Troubleshooting 16 Power supply 230V 50 Hz 10 Class II insulation Operating time 4 minutes Electrical powers TYMOOV 10F 60 W TYMOOV 20F 90 W Weighted noise pressure level A LpA 70 dB A Degree of protection IP 44 Operating temperature 20 ...

Page 5: ...logue Model Length for drilling L Total length TYMOOV 10 Nm and 20 Nm 395 mm 422 mm Tube L length for drilling wheel attachment by screws or rivet 1 3 Motor head position The motor head must be positioned on the mount such that the cable outlet is in the lower part when seen horizontally 1 4 Attaching the motor to the mount Push the tube motor A onto the mount B until it locks into place click 8 N...

Page 6: ...is cable cannot be placed outdoors unless it is inside a UV resistant duct For an outdoor use the motor must be equipped with a RNF or RRF rubber cable with at least 2 carbon Contact the sales department Connection a with fixed or temporary position reversing mechanism A change over switch prohibiting the buttons or from being pressed simultaneously must be used In the case where a change over swi...

Page 7: ...lade Press and hold the button briefly until the shutter reaches the upper stop The stop position will now be automatically set The motor will be activated once Press and hold the button until the shutter locks against the lower stop The stop position will now be automatically set Press and hold the button until the shutter locks against the lower stop The stop position will now be automatically s...

Page 8: ... to the system again The stops have now been cleared You can store them over again 4 2 By the inverter 2 options 4 2 1 From the lower position Lower the shutter completely Press O STOP within 5 seconds following the stop of the shutter Then perform the following sequence O O at 3 second intervals then long press on The motor briefly starts twice The 2 stops have now been cleared OR 4 2 2 From the ...

Page 9: ...end of travel points are not applied Check the mechanical components of the system stabilisation play distortion etc Check whether there is a fault linked to the end of travel settings and reset them Reversal of the direction of rotation when the stops are already set Raise the shutter completely Press O STOP within 5 seconds following the stop of the shutter Then perform the following sequence O ...

Page 10: ...www deltadore com 04 20 ...

Reviews: