background image

EN

4

5

Recommendations

- Cables going through a metal wall must be protected and isolated 

by a sleeve. 
The TYMOOV xF cable can be disassembled.

- If the power cable is damaged, it must be replaced by the 

manufacturer, after-sales service or similarly qualified personnel in 

order to prevent hazards.

- The motor must be chosen according to the requirements of 

the load bearing support. See our charts for selecting the motor 
according to the shutter type. A plate on the motor indicates the 
nominal torque and operating time.

- TYMOOV xF tubular motors are designed to operate intermittently 

(4 minutes of continuous operation). They are electronically 
protected to prevent overheating. If there is a thermal shutdown, 
the motor will operate again after a time period of approximately 
30 minutes. To operate again for 4 minutes, the performance motor 
must have returned to room temperature.

DELTADORE hereby declares that the motorised systems covered by these 

instructions comply with the essential requirements set out by the Machinery 

Directive 2006/42/EC and the European directive RED 2014/53/EU.

The EU declaration for this equipment is available on request 

from:

Service “Info techniques”

DELTADORE – 35270 Bonnemain (France)

email: [email protected]

DELTA DORE

35270 - BONNEMAIN - France

[email protected]

Because of changes in standards and equipment, the characteristics given in the text and the illustrations in this 

document are not binding unless confirmed by our departments.

Summary of Contents for TYMOOV 10F

Page 1: ...EN Tubular Motor range TYMOOV 10F 20F ...

Page 2: ...must be installed at a height of at least 1 5 m The fixed control devices must be installed in a visible area Frequently check the equipment to detect any imbalances or signs of wear or damage to cables and springs Do not use the device when repairs or adjustments are required Preliminary elements Sufficiently rigid roller shutter blades should be used When the roller shutter is closed the apron m...

Page 3: ... protected to prevent overheating If there is a thermal shutdown the motor will operate again after a time period of approximately 30 minutes To operate again for 4 minutes the performance motor must have returned to room temperature DELTADORE hereby declares that the motorised systems covered by these instructions comply with the essential requirements set out by the Machinery Directive 2006 42 E...

Page 4: ...matic stops 12 3 3 Setting 1 manual stop 1 automatic stop 13 3 4 Setting 2 manual stops 14 4 Clearing stops 15 4 1 By wiring 15 4 2 By the inverter 2 options 15 5 Troubleshooting 16 Power supply 230V 50 Hz 10 Class II insulation Operating time 4 minutes Electrical powers TYMOOV 10F 60 W TYMOOV 20F 90 W Weighted noise pressure level A LpA 70 dB A Degree of protection IP 44 Operating temperature 20 ...

Page 5: ...logue Model Length for drilling L Total length TYMOOV 10 Nm and 20 Nm 395 mm 422 mm Tube L length for drilling wheel attachment by screws or rivet 1 3 Motor head position The motor head must be positioned on the mount such that the cable outlet is in the lower part when seen horizontally 1 4 Attaching the motor to the mount Push the tube motor A onto the mount B until it locks into place click 8 N...

Page 6: ...is cable cannot be placed outdoors unless it is inside a UV resistant duct For an outdoor use the motor must be equipped with a RNF or RRF rubber cable with at least 2 carbon Contact the sales department Connection a with fixed or temporary position reversing mechanism A change over switch prohibiting the buttons or from being pressed simultaneously must be used In the case where a change over swi...

Page 7: ...lade Press and hold the button briefly until the shutter reaches the upper stop The stop position will now be automatically set The motor will be activated once Press and hold the button until the shutter locks against the lower stop The stop position will now be automatically set Press and hold the button until the shutter locks against the lower stop The stop position will now be automatically s...

Page 8: ... to the system again The stops have now been cleared You can store them over again 4 2 By the inverter 2 options 4 2 1 From the lower position Lower the shutter completely Press O STOP within 5 seconds following the stop of the shutter Then perform the following sequence O O at 3 second intervals then long press on The motor briefly starts twice The 2 stops have now been cleared OR 4 2 2 From the ...

Page 9: ...end of travel points are not applied Check the mechanical components of the system stabilisation play distortion etc Check whether there is a fault linked to the end of travel settings and reset them Reversal of the direction of rotation when the stops are already set Raise the shutter completely Press O STOP within 5 seconds following the stop of the shutter Then perform the following sequence O ...

Page 10: ...www deltadore com 04 20 ...