Recommendations

WARNING: Important security instructions

Incorrect installation may cause severe injury 

Follow all the instructions and keep this installation guide in a safe 

place.

- TYMOOV xF motors are designed solely for the operation of 

roller shutters for home use. For any other use, please contact our 
technical department.

- The minimum inner diameter of the roller tube is 47 mm, but the 

tube must be chosen according to the weight and length of the 
apron. Consult the tube manufacturers’ charts.

- Do not operate the roller shutter if people or objects are in the 

movement area. 

- The moving parts of the motor, installed at a height of less than 

2.5m, must be protected.

- Before installing the motor, remove all superfluous cords and take 

out of service any equipment not required for the motor to operate.

- IMPORTANT: Do not operate the shutters or cut off their power 

supply when maintenance or cleaning work is being carried out on 
the equipment or in close proximity (e.g. window cleaning).

- Monitor the shutter when it is moving and stand clear until it is 

completely closed.

Do not allow children to play with the fixed control devices. Keep 

remote control devices out of the reach of children.

- The operating device of an unlockable switch must be in direct view 

of the driven part, but kept away from the moving parts. It must be 

installed at a height of at least 1.5 m.

- The fixed control devices must be installed in a visible area.

- Frequently check the equipment to detect any imbalances or signs 

of wear or damage to cables and springs.  

- Do not use the device when repairs or adjustments are required.

 

Preliminary elements

- Sufficiently rigid roller shutter blades should be used.

- When the roller shutter is closed, the apron must not overlap the 

runners by more than one 1/2 blade (max.).

- The apron fastenings or automatic fasteners used on the shutter 

must comply with the recommendations for use provided by the 
manufacturer 
The maximum locked rotor torques for TYMOOV xF motors are:  
10 Nm:  15Nm / 20 Nm: 27 Nm 
Models which cannot support these torques cannot be mounted. 
The number of fasteners must be adjusted according to the model 
and number of links.

- If used with upper stops, preferably use systems built into the 

runners.

- Pay attention to the frame rigidity with stop systems on the shutter 

blades.

- TYMOOV xF motors check the physical stops every 100 

operations, so the motor automatically compensates for any apron 
movement.

- Correct operation of the motor is ensured if it is installed and used 

according to the following recommendations.  
The peripheral elements such as the roller tube, supports, 
fastenings, etc. must be chosen correctly and assembled in 
compliance with good practice. Furthermore, the motor operating 
environment and power required are elements that must be 
carefully chosen and assessed.

- A-weighted sound pressure level: LpA ≤ 70 dB(A).

Summary of Contents for TYMOOV 10F

Page 1: ...EN Tubular Motor range TYMOOV 10F 20F ...

Page 2: ...must be installed at a height of at least 1 5 m The fixed control devices must be installed in a visible area Frequently check the equipment to detect any imbalances or signs of wear or damage to cables and springs Do not use the device when repairs or adjustments are required Preliminary elements Sufficiently rigid roller shutter blades should be used When the roller shutter is closed the apron m...

Page 3: ... protected to prevent overheating If there is a thermal shutdown the motor will operate again after a time period of approximately 30 minutes To operate again for 4 minutes the performance motor must have returned to room temperature DELTADORE hereby declares that the motorised systems covered by these instructions comply with the essential requirements set out by the Machinery Directive 2006 42 E...

Page 4: ...matic stops 12 3 3 Setting 1 manual stop 1 automatic stop 13 3 4 Setting 2 manual stops 14 4 Clearing stops 15 4 1 By wiring 15 4 2 By the inverter 2 options 15 5 Troubleshooting 16 Power supply 230V 50 Hz 10 Class II insulation Operating time 4 minutes Electrical powers TYMOOV 10F 60 W TYMOOV 20F 90 W Weighted noise pressure level A LpA 70 dB A Degree of protection IP 44 Operating temperature 20 ...

Page 5: ...logue Model Length for drilling L Total length TYMOOV 10 Nm and 20 Nm 395 mm 422 mm Tube L length for drilling wheel attachment by screws or rivet 1 3 Motor head position The motor head must be positioned on the mount such that the cable outlet is in the lower part when seen horizontally 1 4 Attaching the motor to the mount Push the tube motor A onto the mount B until it locks into place click 8 N...

Page 6: ...is cable cannot be placed outdoors unless it is inside a UV resistant duct For an outdoor use the motor must be equipped with a RNF or RRF rubber cable with at least 2 carbon Contact the sales department Connection a with fixed or temporary position reversing mechanism A change over switch prohibiting the buttons or from being pressed simultaneously must be used In the case where a change over swi...

Page 7: ...lade Press and hold the button briefly until the shutter reaches the upper stop The stop position will now be automatically set The motor will be activated once Press and hold the button until the shutter locks against the lower stop The stop position will now be automatically set Press and hold the button until the shutter locks against the lower stop The stop position will now be automatically s...

Page 8: ... to the system again The stops have now been cleared You can store them over again 4 2 By the inverter 2 options 4 2 1 From the lower position Lower the shutter completely Press O STOP within 5 seconds following the stop of the shutter Then perform the following sequence O O at 3 second intervals then long press on The motor briefly starts twice The 2 stops have now been cleared OR 4 2 2 From the ...

Page 9: ...end of travel points are not applied Check the mechanical components of the system stabilisation play distortion etc Check whether there is a fault linked to the end of travel settings and reset them Reversal of the direction of rotation when the stops are already set Raise the shutter completely Press O STOP within 5 seconds following the stop of the shutter Then perform the following sequence O ...

Page 10: ...www deltadore com 04 20 ...

Reviews: