Pre p a ra t i o n   f o r   u s e

HOW TO USE THE AIRCONDITIONER WITH WATER

These air conditioners can use both air and water to cool the condenser (the hot part) of the air
conditioner.

To utilise  the full potential of your air conditioner, the tank 

needs to be filled with water. The water

is used. To increase the cooling power and reduce the noise level and energy consumption of the air
conditioner. The water that is used in then expelled from the machine as water vapour through the
exhaust hose 

(it does not go into room).

Always use clean top water (which doesn’t contain salts). As a rule the water will usually last about 8
hours however this depends on the conditions within the room, such as temperature, humidity, insula-
tion and aspect and number of people. In turbo mode the water will also be used more quickly.

You may also use the airconditioner on air cooling only  (without filling the water tank . If you only requi-
re the lower cooling power.

22

6

A) To  open the front panel

grip either side of the

panel and gently pull the

panel  towards  you and

upwards. Remove the tank

Lifting it forward.

6

4

B) Turn the tank upside down

and remove the plug,
remove the extendible
tube and fill the tank, lea-
ving it on the ground.

C) After  completing the fil-

ling procedure, replace
the extendible hose,
replace the cap and
screw it in tightly.  Return
the tank to its place, with
the writing FRONT clearly
visible. Carefully hold the
panel in the centre and
lower to its closed posi-
tion.

During the "water functioning" operation and in particularly silent locations (eg the bedroom) a 
slight gurgling sound may be heard.  This is completely normal.

IN HIGH HUMIDITY CONDITIONS
Water is extracted from the air in the room, this water is also used to cool the condenser. When
the humidity is particulary high an excess of water may buid up in the internal tank. This can be

drained by removing the bung from the drain hose  

and draining into a suitable receptacle.

11

IMPORTANT: if the room temperature is 32°C or over the airconditioner must be operated with with
water in the tank.

2

GB-5751010800  26-01-2004  16:27  Pagina 20

Summary of Contents for PAC 46ECO

Page 1: ...y causing a fire hazard This appliance must be utilised and installed only in rooms with a total volume of 15 cubic metres or greater The refrigerant used in this appliance would cause damage to the o...

Page 2: ...into the room In single unit models Pinguino a small part of this air is used to cool the refrigerant gas befo re hot and moist air is being discharged outside In suitcase models the cir cuit is coole...

Page 3: ...the exhaust hose to the coupling on the back of the unit as shown in figu re A 10 22 With a double casement window use the suckers provided to hold the two hal ves of the window together fig C 24 Fix...

Page 4: ...tside wall or through the glass of a window Check the height and dimensions given in figure D 30 cm 30 cm 106 MAX 120 cm MIN 30 cm When the hose is not attached close the hole with the bung on the fla...

Page 5: ...To open the front panel grip either side of the panel and gently pull the panel towards you and upwards Remove the tank Lifting it forward 6 4 B Turn the tank upside down and remove the plug remove t...

Page 6: ...ointer N B Never turn the dial in an anti clockwise direction The timer is in effect an electric clock and works only if the plug is connected to the power supply Whenever the plug is discon nected or...

Page 7: ...ery warm room quickly down to a more comfor table level In this case Make sure that the tank is full of water see page 22 Make sure that the function selector switch is in the large crystal position 1...

Page 8: ...Do not obstruct the air intake or outlet Make sure there are no heat sources in the room Do not use outdoors 2 8 PROBLEM WARNING LIGHT The lighted pilot light indicates that the safety device of the p...

Page 9: ...following method turn off the appliance and remove the plug from the electrical outlet open the front panel and remove the tank remove the bung from the drainage hose which can be found at the back th...

Page 10: ...ur 4 After this drain out all of the liquid remai ning in the collection reservoir and rinse thoroughly During the rinsing process the drainage hose must be open and the appliance functioning 5 Unplug...

Page 11: ...people the air outlet hose has come detached from the coupling thermostat adjusted too high air filters clogged the output of the unit is insufficient for the con ditions or size of the room wait thr...

Page 12: ...he fuse using a 13 Amp Asta approved fuse to BS 1362 In the event of losing the fuse cover the plug must NOT be used until a replacement fuse cover can be obtained from your nea rest electrical dealer...

Reviews: