ENGLISH

S e t t i n g   u p

AIR CONDITIONING WITH INSTALLATION

For more efficient use Pinguino can also be
semi-permanently installed 

Fit the flange 

supplied to the hole.

Fix the hose  

to the coupling on the

back of the unit (figure 

A

).

Attach the end of the hose

to the flan-

ge 

as shown in the figure 

E

.

21

22

22

21

To install, proceed as follows:

Make a hole in a outside wall or through
the glass of a window. Check the height
and dimensions given in figure

D

30 cm

30 cm

106

MAX 120 cm

MIN 30 cm

When the hose 

is not attached, close  the

hole with the bung on the flange 

.

NOTE: 

When the unit is installed semi-permanently,

we recommend leaving a door slightly open

(1 cm is enough) to ensure an adequate

exchange of air.

21

22

in a window
pane

in the wall: for
optimum results,
insulate the sec-
tion of the wall
with suitable
i n s u - l a t i n g
material.

in the
wood sill of
a window

D

E

GB-5751010800  26-01-2004  16:27  Pagina 19

Summary of Contents for PAC 46ECO

Page 1: ...y causing a fire hazard This appliance must be utilised and installed only in rooms with a total volume of 15 cubic metres or greater The refrigerant used in this appliance would cause damage to the o...

Page 2: ...into the room In single unit models Pinguino a small part of this air is used to cool the refrigerant gas befo re hot and moist air is being discharged outside In suitcase models the cir cuit is coole...

Page 3: ...the exhaust hose to the coupling on the back of the unit as shown in figu re A 10 22 With a double casement window use the suckers provided to hold the two hal ves of the window together fig C 24 Fix...

Page 4: ...tside wall or through the glass of a window Check the height and dimensions given in figure D 30 cm 30 cm 106 MAX 120 cm MIN 30 cm When the hose is not attached close the hole with the bung on the fla...

Page 5: ...To open the front panel grip either side of the panel and gently pull the panel towards you and upwards Remove the tank Lifting it forward 6 4 B Turn the tank upside down and remove the plug remove t...

Page 6: ...ointer N B Never turn the dial in an anti clockwise direction The timer is in effect an electric clock and works only if the plug is connected to the power supply Whenever the plug is discon nected or...

Page 7: ...ery warm room quickly down to a more comfor table level In this case Make sure that the tank is full of water see page 22 Make sure that the function selector switch is in the large crystal position 1...

Page 8: ...Do not obstruct the air intake or outlet Make sure there are no heat sources in the room Do not use outdoors 2 8 PROBLEM WARNING LIGHT The lighted pilot light indicates that the safety device of the p...

Page 9: ...following method turn off the appliance and remove the plug from the electrical outlet open the front panel and remove the tank remove the bung from the drainage hose which can be found at the back th...

Page 10: ...ur 4 After this drain out all of the liquid remai ning in the collection reservoir and rinse thoroughly During the rinsing process the drainage hose must be open and the appliance functioning 5 Unplug...

Page 11: ...people the air outlet hose has come detached from the coupling thermostat adjusted too high air filters clogged the output of the unit is insufficient for the con ditions or size of the room wait thr...

Page 12: ...he fuse using a 13 Amp Asta approved fuse to BS 1362 In the event of losing the fuse cover the plug must NOT be used until a replacement fuse cover can be obtained from your nea rest electrical dealer...

Reviews: