background image

24

Before cleaning or maintenance, always turn the

unit off by placing the selector in the “O” position

and unplug from the mains.

CLEANING THE APPLIANCE

We recommend cleaning the appliance with
a slightly damp cloth then drying with a dry
cloth. For safety reasons, do not wash the air
conditioner with water.  

Precautions

Never clean with benzene, alcohol or sol-
vents. Never spray liquid insecticide or similar.

CLEANING THE FILTERS
Dust filter

All of the models are equipped with a dust fil-
ter able to capture the dust particles suspen-
ded in the air.
In order to maintain the effectiveness of your
air conditioner unaltered over time, remem-
ber to clean the dust filter every two weeks.
1. Remove the aspiration grill 

, (see fig. 

F

);

8

1

2

Purification filter 

Clean the external side of the purification fil-
ter once a week.  Use a vacuum cleaner at
an intermediate power level.  Never clean
the inside of the filter. Replace the purification
filter at the end of each season or in any
case, when it is no longer effective.  The puri-
fication filter can be purchased in the store as
an accessory or at an Authorised Service
Centre as a replacement part.  Alternatively,
the dust filter included with the appliance
may be used in place of the purification filter.

CLEANING THE RESORVOIR 

It is recommended that you clean this at least
once a month using the following method:

turn off the appliance and remove the
plug from the electrical outlet.

open the front panel 

and remove the

tank .

remove the bung from the drainage hose

which can be found at the back the

air conditioner and empty out the water
to a container.

after draining off the water, replace the
drainage hose plug.

remove the dirt by scrubbing gently with a
cloth where the tank is positioned.

START OF SEASON CHECKS

Check that the power cable and socket are
undamaged and that the earth installation is
efficient.

Carefully  observe the installation

instructions.

RECOMMENDED OPERATIONS TO
PERFORM AT THE END OF THE SEASON

1) Proceed with scaling procedures (see

page 25).

2) Remove the water from the collection

reservoir .

3) Operate the appliance in the ventilation

only mode for about half an hour in order
to thoroughly dry the inside of the air con-
ditioner.

4) Turn off the appliance and remove the

plug from the outlet.

5) Remove the exhaust hose .
6) Clean the filter and dry it thoroughly befo-

re replacing it in the appliance.

22

5

11

6

4

5

fig. 

F

M a i n t e n a n c e

2. Remove the filter holder housing by deta-
ching it from the external grill.  To detach it,
press on the two wings found on the side of
the filter holder (see fig. 

G

)

Use a vacuum cleaner to remove the dust
deposits on the filter.  If the filter is very dirty,

immerse it in warm water, rinsing it thoroughly.
The temperature of the water should be kept
under 40°C.
After washing it, let the filter dry before re-
inserting it into the holder.

fig. 

G

GB-5751010800  26-01-2004  16:27  Pagina 24

Summary of Contents for PAC 46ECO

Page 1: ...y causing a fire hazard This appliance must be utilised and installed only in rooms with a total volume of 15 cubic metres or greater The refrigerant used in this appliance would cause damage to the o...

Page 2: ...into the room In single unit models Pinguino a small part of this air is used to cool the refrigerant gas befo re hot and moist air is being discharged outside In suitcase models the cir cuit is coole...

Page 3: ...the exhaust hose to the coupling on the back of the unit as shown in figu re A 10 22 With a double casement window use the suckers provided to hold the two hal ves of the window together fig C 24 Fix...

Page 4: ...tside wall or through the glass of a window Check the height and dimensions given in figure D 30 cm 30 cm 106 MAX 120 cm MIN 30 cm When the hose is not attached close the hole with the bung on the fla...

Page 5: ...To open the front panel grip either side of the panel and gently pull the panel towards you and upwards Remove the tank Lifting it forward 6 4 B Turn the tank upside down and remove the plug remove t...

Page 6: ...ointer N B Never turn the dial in an anti clockwise direction The timer is in effect an electric clock and works only if the plug is connected to the power supply Whenever the plug is discon nected or...

Page 7: ...ery warm room quickly down to a more comfor table level In this case Make sure that the tank is full of water see page 22 Make sure that the function selector switch is in the large crystal position 1...

Page 8: ...Do not obstruct the air intake or outlet Make sure there are no heat sources in the room Do not use outdoors 2 8 PROBLEM WARNING LIGHT The lighted pilot light indicates that the safety device of the p...

Page 9: ...following method turn off the appliance and remove the plug from the electrical outlet open the front panel and remove the tank remove the bung from the drainage hose which can be found at the back th...

Page 10: ...ur 4 After this drain out all of the liquid remai ning in the collection reservoir and rinse thoroughly During the rinsing process the drainage hose must be open and the appliance functioning 5 Unplug...

Page 11: ...people the air outlet hose has come detached from the coupling thermostat adjusted too high air filters clogged the output of the unit is insufficient for the con ditions or size of the room wait thr...

Page 12: ...he fuse using a 13 Amp Asta approved fuse to BS 1362 In the event of losing the fuse cover the plug must NOT be used until a replacement fuse cover can be obtained from your nea rest electrical dealer...

Reviews: