background image

24

Before cleaning or maintaining the unit, always
turn the unit off by releasing the button        
and unplug from the mains 

.

CLEANING THE APPLIANCE

We recommend cleaning the appliance with
a slightly damp cloth then drying with a dry
cloth. For safety reasons, do not wash the air
conditioner with water.  

Precautions

Never clean with benzene, alcohol or sol-
vents. Never spray liquid insecticide or similar.

CLEANING THE FILTERS
Dust filter

All of the models are equipped with a dust fil-
ter able to capture the dust particles suspen-
ded in the air.
In order to maintain the effectiveness of your
air conditioner unaltered over time, remem-
ber to clean the dust filter every two weeks.
1. Remove the aspiration grill 

, (see fig. 

F

);

2. Remove the filter holder housing by deta-
ching it from the external grill.  To detach it,
press on the two wings found on the side of
the filter holder (see fig. 

G

)

Use a vacuum cleaner to remove the dust
deposits on the filter.  If the filter is very dirty,

6

12

1

2

CLEANING THE RESORVOIR 

It is recommended that you clean this at least
once a month using the following method:

turn off the appliance and remove the
plug from the electrical outlet.

open the front panel 

and remove the

tank .

Open the little gate 

which can be

found at the back of the air conditioner,
remove the bung  

from the drainage

hose 

and empty out the water to a

container.

after draining off the water, replace the
drainage hose plug.

remove the dirt by scrubbing gently with a
cloth where the tank is positioned.

START OF SEASON CHECKS

Check that the power cable and socket are
undamaged and that the earth installation is
efficient.

Carefully  observe the installation

instructions.

RECOMMENDED OPERATIONS TO
PERFORM AT THE END OF THE SEASON

1) Proceed with scaling procedures (see

page 25).

2) Remove the water from the collection

reservoir .

3) Operate the appliance in the ventilation

only mode for about half an hour in order
to thoroughly dry the inside of the air con-
ditioner.

4) Turn off the appliance and remove the

plug from the outlet.

5) Remove the drainage hose 

.

6) Clean the filter and dry it thoroughly befo-

re replacing it in the appliance.

7) Cover the appliance so that  dust does

not build up.

20

4

10

9

8

5

3

4

fig. 

F

M a i n t e n a n c e

immerse it in warm water, rinsing it thoroughly.
The temperature of the water should be kept
under 40°C.
After washing it, let the filter dry before re-
inserting it into the holder.

fig. 

G

GB-5751010700  15-01-2004  16:33  Pagina 24

Summary of Contents for PAC 46

Page 1: ...maintenance operations always unplug the unit from the socket Do not pull on or place strain on the power cable when moving the appliance The appliance should not be installed where the atmosphere may...

Page 2: ...her in the home or even transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas removing excess heat and moistu re before being discharged a...

Page 3: ...the exhaust hose to the coupling on the back of the unit as shown in figu re A 7 20 With a double casement window use the suckers provided to hold the two hal ves of the window together fig C 22 Fix t...

Page 4: ...roceed as follows Make a hole in a outside wall or through the glass of a window Check the height and dimensions given in figure D 30 cm 30 cm 98 MAX 120 cm MIN 30 cm When the hose is not attached clo...

Page 5: ...To open the front panel grip either side of the panel and gently pull the panel towards you and upwards Remove the tank Lifting it forward 5 2 3 B Turn the tank upside down and remove the plug remove...

Page 6: ...ches on the dial corresponding to the period required each notch represents 15 mins 2 Press the TIMER key the signal light will come ON 3 Make sure that the timer indicates the cor rect time see instr...

Page 7: ...light will turn off The temperature selected in this way will automatically be regulated and maintained and save energy When regulating the ther mostat the air conditioning function is tem porarily i...

Page 8: ...antee an adequate exchange of air Protect the room from direct exposure to the sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do not rest obje...

Page 9: ...ove the plug from the electrical outlet open the front panel and remove the tank Open the little gate which can be found at the back of the air conditioner remove the bung from the drainage hose and e...

Page 10: ...air conditioner for about half an hour 4 After this drain out all of the liquid remai ning in the collection reservoir and rinse thoroughly During the rinsing process the drainage hose must be open an...

Page 11: ...le the air outlet hose has come detached from the coupling thermostat adjusted too high air filters clogged the output of the unit is insufficient for the con ditions or size of the room wait three mi...

Page 12: ...lded on type the fuse cover must be re fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362 In the event of losing the fuse cover the plug must NOT be used until a replacement fu...