RECOMMENDED OPERATING CONDITIONS

WHEN CONDITIONING

Room temperature

21 ÷ 32°C

TECHNICAL SPECIFICATION

Power supply

see rating plate

Max. absorbed power 
in air conditioning

Refrigerating capacity

Refrigerant

Max. absorbed power 
when heating

Number of fan speeds

2

Max. air flow .

370 m

3

/h

Dimensions:

width

580 mm

height

785 mm

depth 435 

mm

Technical specification

ELECTRICAL CONNECTION (U.K. ONLY)

A) If your appliance comes fitted with a plug, it will incorporate a 13 Amp fuse. If it does not fit your socket, the plug should

be cut off from the mains lead, and on appropriate plug fitted, as below. warning: Very carefully dispose of the cut off
plug after removing the fuse: do not insert in a 13 Amp socket elsewhere in the house as this could cause a shock hazard.
With alternative plugs not incorporating a fuse, the circuit must be protected by a 15 Amp fuse. If the plug is a moulded-
on type, the fuse cover must be re-fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362. In the
event of losing the fuse cover, the plug must NOT be used until a replacement fuse cover can be obtained from your nea-
rest electrical dealer. The colour of the correct replacement fuse cover is that as marked on the base of the plug.

B) If your appliance is not fitted with a plug, please follow the instructins provided below:

WARNING - THIS APPLIANCE MUST BE EARTHED

IMPORTANT

The wires in the mains lead are coloured in accordance with
the following code:

Green and yellow Earth
Blue

Neutral

Brown

Live

As the colours of the wires in the mains lead may not corre-
spond with the coloured markings identifying the terminals
in your plug, proceed as follows:
The green and yellow wire must be connected to the termi-
nal in the plug marked with the letter E or the earth symbol   

or coloured green or green and yellow.

The blue wire must be connected to the terminal marked with
the letter N or coloured black.
The brown wire must be connected to the terminal marked
with the letter L or coloured red.

GB-5751010700  15-01-2004  16:33  Pagina 27

Summary of Contents for PAC 46

Page 1: ...maintenance operations always unplug the unit from the socket Do not pull on or place strain on the power cable when moving the appliance The appliance should not be installed where the atmosphere may...

Page 2: ...her in the home or even transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas removing excess heat and moistu re before being discharged a...

Page 3: ...the exhaust hose to the coupling on the back of the unit as shown in figu re A 7 20 With a double casement window use the suckers provided to hold the two hal ves of the window together fig C 22 Fix t...

Page 4: ...roceed as follows Make a hole in a outside wall or through the glass of a window Check the height and dimensions given in figure D 30 cm 30 cm 98 MAX 120 cm MIN 30 cm When the hose is not attached clo...

Page 5: ...To open the front panel grip either side of the panel and gently pull the panel towards you and upwards Remove the tank Lifting it forward 5 2 3 B Turn the tank upside down and remove the plug remove...

Page 6: ...ches on the dial corresponding to the period required each notch represents 15 mins 2 Press the TIMER key the signal light will come ON 3 Make sure that the timer indicates the cor rect time see instr...

Page 7: ...light will turn off The temperature selected in this way will automatically be regulated and maintained and save energy When regulating the ther mostat the air conditioning function is tem porarily i...

Page 8: ...antee an adequate exchange of air Protect the room from direct exposure to the sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do not rest obje...

Page 9: ...ove the plug from the electrical outlet open the front panel and remove the tank Open the little gate which can be found at the back of the air conditioner remove the bung from the drainage hose and e...

Page 10: ...air conditioner for about half an hour 4 After this drain out all of the liquid remai ning in the collection reservoir and rinse thoroughly During the rinsing process the drainage hose must be open an...

Page 11: ...le the air outlet hose has come detached from the coupling thermostat adjusted too high air filters clogged the output of the unit is insufficient for the con ditions or size of the room wait three mi...

Page 12: ...lded on type the fuse cover must be re fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362 In the event of losing the fuse cover the plug must NOT be used until a replacement fu...

Reviews: