background image

20

Pre p a ra t i o n   f o r   u s e

HOW TO USE THE AIRCONDITIONER WITH WATER

These air conditioners can use both air and water to cool the condenser (the hot part) of the air
conditioner.

To utilise  the full potential of your air conditioner, the tank 

needs to be filled with water. The water

is used. To increase the cooling power and reduce the noise level and energy consumption of the air
conditioner. The water that is used in then expelled from the machine as water vapour through the
exhaust hose 

(it does not go into room).

Always use clean top water (which doesn’t contain salts). As a rule the water will usually last about 8
hours however this depends on the conditions within the room, such as temperature, humidity, insula-
tion and aspect and number of people. In turbo mode the water will also be used more quickly.

You may also use the airconditioner on air cooling only  (without filling the water tank ). If you only requi-
re the lower cooling power.

20

5

A) To  open the front panel

grip either side of the

panel 

and gently pull

the panel  towards  you and

upwards. Remove the tank

Lifting it forward.

5

2

3

B) Turn the tank upside down

and remove the plug,
remove the extendible
tube and fill the tank, lea-
ving it on the ground.

C) After  completing the fil-

ling procedure, replace
the extendible hose,
replace the cap and
screw it in tightly.  Return
the tank to its place, with
the writing FRONT clearly
visible. Carefully hold the
panel in the centre and
lower to its closed posi-
tion.

During the "water functioning" operation and in particularly silent locations (eg the bedroom) a 
slight gurgling sound may be heard.  This is completely normal.

IN HIGH HUMIDITY CONDITIONS
Water is extracted from the air in the room, this water is also used to cool the condenser. When
the humidity is particulary high an excess of water may buid up in the internal tank. This can be

drained by removing the bung from the drain hose  

and draining into a suitable receptacle.

10

IMPORTANT: if the room temperature is 32°C or over the airconditioner must be operated with with
water in the tank.

2

GB-5751010700  15-01-2004  16:33  Pagina 20

Summary of Contents for PAC 46

Page 1: ...maintenance operations always unplug the unit from the socket Do not pull on or place strain on the power cable when moving the appliance The appliance should not be installed where the atmosphere may...

Page 2: ...her in the home or even transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas removing excess heat and moistu re before being discharged a...

Page 3: ...the exhaust hose to the coupling on the back of the unit as shown in figu re A 7 20 With a double casement window use the suckers provided to hold the two hal ves of the window together fig C 22 Fix t...

Page 4: ...roceed as follows Make a hole in a outside wall or through the glass of a window Check the height and dimensions given in figure D 30 cm 30 cm 98 MAX 120 cm MIN 30 cm When the hose is not attached clo...

Page 5: ...To open the front panel grip either side of the panel and gently pull the panel towards you and upwards Remove the tank Lifting it forward 5 2 3 B Turn the tank upside down and remove the plug remove...

Page 6: ...ches on the dial corresponding to the period required each notch represents 15 mins 2 Press the TIMER key the signal light will come ON 3 Make sure that the timer indicates the cor rect time see instr...

Page 7: ...light will turn off The temperature selected in this way will automatically be regulated and maintained and save energy When regulating the ther mostat the air conditioning function is tem porarily i...

Page 8: ...antee an adequate exchange of air Protect the room from direct exposure to the sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do not rest obje...

Page 9: ...ove the plug from the electrical outlet open the front panel and remove the tank Open the little gate which can be found at the back of the air conditioner remove the bung from the drainage hose and e...

Page 10: ...air conditioner for about half an hour 4 After this drain out all of the liquid remai ning in the collection reservoir and rinse thoroughly During the rinsing process the drainage hose must be open an...

Page 11: ...le the air outlet hose has come detached from the coupling thermostat adjusted too high air filters clogged the output of the unit is insufficient for the con ditions or size of the room wait three mi...

Page 12: ...lded on type the fuse cover must be re fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362 In the event of losing the fuse cover the plug must NOT be used until a replacement fu...

Reviews: