If the unit is not working properly, this may be due to small problems that you can easily resolve yourself.

Follow these instructions carefully before contacting your local Authorised Technical Service Centre.

Troubleshooting

PROBLEM

REMEDY

The air conditioner is
completely turned
off

it is not plugged in

there is no electricity

plug in

wait

CAUSE

The unit works but
does not cool the
room

three minutes have not passed since it was
turned on

windows open 

a heat source is operating in the room (burner,
light, etc.) or there are a lot of people

the air outlet hose has come detached from
the coupling

thermostat adjusted too high

air filters clogged

the output of the unit is insufficient for the con-
ditions or size of the room

wait three minutes (safety devi-
ce) before the appliance start
cooling.

•  close the windows
•  eliminate heat sources

•  fit the hose in the coupling

•  lower the thermostat
• clean/replace 

filters

The unit works for
only a short time

there is a kink in the exsaust hose

the exsaust hose is blocked

there are too many curves in the outlet tube

the fan is blocked

position the exaust hose correctly

check there are no blockages
preventing the discharge of air
to the outside

rearrange the hose correctly 

contact the Service Centre

GB-5751010700  15-01-2004  16:33  Pagina 26

Summary of Contents for PAC 46

Page 1: ...maintenance operations always unplug the unit from the socket Do not pull on or place strain on the power cable when moving the appliance The appliance should not be installed where the atmosphere may...

Page 2: ...her in the home or even transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas removing excess heat and moistu re before being discharged a...

Page 3: ...the exhaust hose to the coupling on the back of the unit as shown in figu re A 7 20 With a double casement window use the suckers provided to hold the two hal ves of the window together fig C 22 Fix t...

Page 4: ...roceed as follows Make a hole in a outside wall or through the glass of a window Check the height and dimensions given in figure D 30 cm 30 cm 98 MAX 120 cm MIN 30 cm When the hose is not attached clo...

Page 5: ...To open the front panel grip either side of the panel and gently pull the panel towards you and upwards Remove the tank Lifting it forward 5 2 3 B Turn the tank upside down and remove the plug remove...

Page 6: ...ches on the dial corresponding to the period required each notch represents 15 mins 2 Press the TIMER key the signal light will come ON 3 Make sure that the timer indicates the cor rect time see instr...

Page 7: ...light will turn off The temperature selected in this way will automatically be regulated and maintained and save energy When regulating the ther mostat the air conditioning function is tem porarily i...

Page 8: ...antee an adequate exchange of air Protect the room from direct exposure to the sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do not rest obje...

Page 9: ...ove the plug from the electrical outlet open the front panel and remove the tank Open the little gate which can be found at the back of the air conditioner remove the bung from the drainage hose and e...

Page 10: ...air conditioner for about half an hour 4 After this drain out all of the liquid remai ning in the collection reservoir and rinse thoroughly During the rinsing process the drainage hose must be open an...

Page 11: ...le the air outlet hose has come detached from the coupling thermostat adjusted too high air filters clogged the output of the unit is insufficient for the con ditions or size of the room wait three mi...

Page 12: ...lded on type the fuse cover must be re fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362 In the event of losing the fuse cover the plug must NOT be used until a replacement fu...

Reviews: