Setting the timer

SETTING THE TIMER (if supplied)

The programmer/timer 

, like all clocks,

must be set to the exact time. If for example
it is 4.00 pm. (16.00), turn the dial in a clockwi-
se direction (following the direction of the
arrow) until the number 16 is lined up with the
triangular pointer (the arrows indicates 4:00
P.M. approximately ).

14

21

20

19

16

pointer

N.B.: Never turn the dial in an anti-clockwise
direction!

The timer is in effect, an electric clock and
works only if the plug is connected to the
power supply. Whenever the plug is discon-
nected or there is a power failure, the pro-
grammer stops (the clock is then “slow”) and
must be re-set.

PROGRAMMED MODE

1) Set the operating times by pushing out the

notches on the dial corresponding to the
period required (each notch represents 15
mins.)

2) Press the TIMER key

, the  signal light

will come ON.

3) Make sure that the timer indicates the cor-

rect time (see instructions on setting).

15

13

21

20

19

16

Funzionamento

4) Select the desired function as shown in the

chart overleaf.

N.B.: To override the programmed operating

times, simply press the ON/OFF key 

(the

timer signal lamp ON will go out)

13

operating time

ELECTRICAL CONNECTION

Before plugging in check that:

the mains supply corresponds to the
power supply shown on the rating plate;

the socket and the mains lead correspond
to the power requirements of the applian-
ce;

the socket  is suited to the plug, otherwise
have the socket replaced;

the socket is properly grounded. 

The manufactures cannot be held responsi-
ble for any damages due to failure in fol-
lowing normal safety procedures.

Replacement of the power cable must be
carried out by qualified personnel.

GB-5751010700  15-01-2004  16:33  Pagina 21

Summary of Contents for PAC 46

Page 1: ...maintenance operations always unplug the unit from the socket Do not pull on or place strain on the power cable when moving the appliance The appliance should not be installed where the atmosphere may...

Page 2: ...her in the home or even transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas removing excess heat and moistu re before being discharged a...

Page 3: ...the exhaust hose to the coupling on the back of the unit as shown in figu re A 7 20 With a double casement window use the suckers provided to hold the two hal ves of the window together fig C 22 Fix t...

Page 4: ...roceed as follows Make a hole in a outside wall or through the glass of a window Check the height and dimensions given in figure D 30 cm 30 cm 98 MAX 120 cm MIN 30 cm When the hose is not attached clo...

Page 5: ...To open the front panel grip either side of the panel and gently pull the panel towards you and upwards Remove the tank Lifting it forward 5 2 3 B Turn the tank upside down and remove the plug remove...

Page 6: ...ches on the dial corresponding to the period required each notch represents 15 mins 2 Press the TIMER key the signal light will come ON 3 Make sure that the timer indicates the cor rect time see instr...

Page 7: ...light will turn off The temperature selected in this way will automatically be regulated and maintained and save energy When regulating the ther mostat the air conditioning function is tem porarily i...

Page 8: ...antee an adequate exchange of air Protect the room from direct exposure to the sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do not rest obje...

Page 9: ...ove the plug from the electrical outlet open the front panel and remove the tank Open the little gate which can be found at the back of the air conditioner remove the bung from the drainage hose and e...

Page 10: ...air conditioner for about half an hour 4 After this drain out all of the liquid remai ning in the collection reservoir and rinse thoroughly During the rinsing process the drainage hose must be open an...

Page 11: ...le the air outlet hose has come detached from the coupling thermostat adjusted too high air filters clogged the output of the unit is insufficient for the con ditions or size of the room wait three mi...

Page 12: ...lded on type the fuse cover must be re fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362 In the event of losing the fuse cover the plug must NOT be used until a replacement fu...

Reviews: