CARE OF YOUR METER 
 

To keep your meter in good working order: 
 

 

Store your meter in a clean, dry place. The protective carrying case provided is an ideal 
storage place when the meter is not in use. 

 

Change the 9-Volt battery as needed. Continued use with a low battery may cause the 
meter to go out of calibration.  

 

Clean the meter and probes with any biodegradable cleaner. Use the cleaner sparingly 
and on external parts only. Keep the cleaner out of the external connector. DO NOT 
IMMERSE THE METER OR ANY ELECTRODE IN WATER. 

 

Remove the battery if the meter will not be used for one month or longer. 

 
 

SERVICE FOR YOUR METER 
 

 

Pack your meter securely. Enclose a purchase order or letter with a brief description of 
the problem. 

 

There is no need to call us for a return authorization number if you are within the EU. 
Customers outside the EU must contact us for more specific instructions prior to 
returning a meter. 

 

Include your name, address, daytime phone and fax numbers or e-mail address. If you 
believe the meter is under warranty, please provide the original sales slip or invoice. 

 

Ship via UPS, Express Mail, Priority Mail or any overnight courier who provides prompt 
service. Do not use standard parcel post. 

 

Insure your instrument for its full value and ship prepaid. We are not responsible for 
damage in transit. 

 

We do not accept COD shipments or cover any incoming freight or duty charges on 
returned merchandise 

 

Turnaround time on repairs is approximately two weeks. 

 

We will call you with an estimate if you specifically request one, or if we determine that 
the meter may be too costly to repair. 

 

Non-warranty repairs will be returned via UPS/COD unless you have already established 
other payment terms. There is no COD service outside the EU. 

 

Payments have to be made by Bank transfer prior to the return shipment. A Proforma 
invoice will be raised in advance. 

 

Warranty repairs will be returned at no charge if shipped within the EU via GLS Ground 
Service. Freight charges for expedited services (i.e., Federal Express, UPS/2 Day, UPS/1 
Day, etc.) are the customer’s responsibility and will be charged as per the above terms. 

 
 

Summary of Contents for F-2000H

Page 1: ...F 2000H HAY AND HOPS MOISTURE METER OPERATION MANUAL v3 6 DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s HERTOGENBOSCH THE NETHERLANDS info delmhorst eu www MoistureMetersDelmhorst com 31 0 73 6395080...

Page 2: ...Testing Baled Hay 5 Testing in the Windrow 7 Factors Affecting Your Reading 7 Range Of Moisture Content 7 Hay Temperature 8 Curing 8 Density 8 Use Of Preservatives 8 Sample Size 9 Testing for hops 10...

Page 3: ...ing erases the readings Scale Button 3 Displays the meter scale hay or hops and acts as a toggle switch to change between two scales Also acts as an arrow button when pressed after the set point butto...

Page 4: ...value To scroll forward to a higher value hold the set point button 4 while the current value is displayed and scroll to the set point value desired To scroll backward through the set point values pre...

Page 5: ...tored in memory TAKING A READING TESTING BALED HAY Connect the probe to the external connector on the top of the meter Insert the probe into the bale Press the read button 1 The meter displays the MC...

Page 6: ...ve This will make the moisture distribution in the sample more uniform Test B Attach the 831 short pin prod to the H 4 handle and connect the handle to the external connector on top of the meter Apply...

Page 7: ...creases so does the conductivity Tests on hay at high moisture content over 25 are less accurate This is mostly due to the variability in moisture distribution The reduced level of accuracy in the hig...

Page 8: ...ll ensure firmer and more uniform contact USE OF PRESERVATIVES Hay preservative or stabilizers may also have an effect on meter readings Normally a bale of hay treated with preservative will read high...

Page 9: ...the moisture level in the hops that is in contact with the uninsulated tip of the prod Therefore it is very important to make a number of tests in all parts of a bale for proper testing Since moistur...

Page 10: ...numbers or e mail address If you believe the meter is under warranty please provide the original sales slip or invoice Ship via UPS Express Mail Priority Mail or any overnight courier who provides pro...

Page 11: ...MHORST be liable for any incidental indirect special or consequential damages of any type whatsoever including but not limited to lost profits or downtime arising out of or related in any respect to t...

Page 12: ...ective Standard s to which Conformity is declared EN 50082 1 1992 EMC Generic immunity standard EN 50081 1 1992 EMC Generic emission standard EN 55011 1991 Limits and methods of measurement of radio d...

Reviews: