DECLARATION OF CONFORMITY 

 

 
 
 
Manufacturer's Name:  

Delmhorst Instrument Co.  

 
Manufacturer's Address: 

51 Indian Lane East  

Towaco, NJ 07082  
USA  
 

Council Directive(s): 

89/336/EEC - Meets EMC directive  

73/23/EEC - Not required. Voltage used or generated 
is not within scope of Low Voltage Directive. 
 

Standard(s) to which Conformity is declared :

 

EN 50082-1:1992- EMC Generic immunity standard 
EN 50081-1:1992- EMC Generic emission standard 
EN 55011:1991- Limits and methods of measurement of 
radio disturbance characteristics of (ISM) equipment. 
 

Type of Product :   

Hay-Hops Moisture Meter 

 

Model No

 

F-2000/H 

 
I, the undersigned, hereby declare that the product specified above conforms  
to the above Directive(s) and Standard(s). 

 

 

 

Thomas Laurenzi, President  
Delmhorst Instrument Co.  
NJ, USA 

 

Summary of Contents for F-2000H

Page 1: ...F 2000H HAY AND HOPS MOISTURE METER OPERATION MANUAL v3 6 DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s HERTOGENBOSCH THE NETHERLANDS info delmhorst eu www MoistureMetersDelmhorst com 31 0 73 6395080...

Page 2: ...Testing Baled Hay 5 Testing in the Windrow 7 Factors Affecting Your Reading 7 Range Of Moisture Content 7 Hay Temperature 8 Curing 8 Density 8 Use Of Preservatives 8 Sample Size 9 Testing for hops 10...

Page 3: ...ing erases the readings Scale Button 3 Displays the meter scale hay or hops and acts as a toggle switch to change between two scales Also acts as an arrow button when pressed after the set point butto...

Page 4: ...value To scroll forward to a higher value hold the set point button 4 while the current value is displayed and scroll to the set point value desired To scroll backward through the set point values pre...

Page 5: ...tored in memory TAKING A READING TESTING BALED HAY Connect the probe to the external connector on the top of the meter Insert the probe into the bale Press the read button 1 The meter displays the MC...

Page 6: ...ve This will make the moisture distribution in the sample more uniform Test B Attach the 831 short pin prod to the H 4 handle and connect the handle to the external connector on top of the meter Apply...

Page 7: ...creases so does the conductivity Tests on hay at high moisture content over 25 are less accurate This is mostly due to the variability in moisture distribution The reduced level of accuracy in the hig...

Page 8: ...ll ensure firmer and more uniform contact USE OF PRESERVATIVES Hay preservative or stabilizers may also have an effect on meter readings Normally a bale of hay treated with preservative will read high...

Page 9: ...the moisture level in the hops that is in contact with the uninsulated tip of the prod Therefore it is very important to make a number of tests in all parts of a bale for proper testing Since moistur...

Page 10: ...numbers or e mail address If you believe the meter is under warranty please provide the original sales slip or invoice Ship via UPS Express Mail Priority Mail or any overnight courier who provides pro...

Page 11: ...MHORST be liable for any incidental indirect special or consequential damages of any type whatsoever including but not limited to lost profits or downtime arising out of or related in any respect to t...

Page 12: ...ective Standard s to which Conformity is declared EN 50082 1 1992 EMC Generic immunity standard EN 50081 1 1992 EMC Generic emission standard EN 55011 1991 Limits and methods of measurement of radio d...