Figure 80. Removing the PSU blank
1
tab at the bottom of PSU blank
2
PSU blank
3
tab on the PSU blank (2)
4
slot on the chassis (2)
5
slot at the bottom of the chassis
Next step
Install the PSU or PSU blank.
Related links
Safety instructions
Before working inside your system
Installing an AC power supply unit
Installing the power supply unit blank
After working inside your system
Installing the power supply unit blank
Prerequisites
CAUTION:
Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE:
Install the power supply unit (PSU) blank only in the second PSU bay.
Follow the safety guidelines listed in the Safety instructions section.
Steps
1
Align the tabs on the PSU blank with the slots on the chassis.
2
Insert the top of the PSU blank into the PSU bay first, and then the bottom.
Ensure that the tabs on the PSU blank engage with the slots on the chassis.
Installing and removing system components
147