Codes and Messages
3-7
Memory
address line
failure at
address, read
value expect-
ing
value
Memory double
word logic
failure at
address, read
value expect-
ing
value
Memory odd/
even logic
failure at
address, read
value expect-
ing
value
Memory write/
read failure
at
address,
read
value
expecting
value
Faulty or improperly
seated DIMMs or defec-
tive system board
Remove and reseat the
DIMMs. If the problem
persists, replace the
DIMMs. If the problem still
persists, replace the sys-
tem board.
Memory allo-
cation error
Faulty application
Restart the application.
Memory
parity
interrupt at
address
Improperly seated or faulty
DIMMs
Remove and reseat the
DIMMs. If the problem
persists, replace the
DIMMs.
Memory tests
terminated
by keystroke
POST memory test termi-
nated by pressing the
<Spacebar>
No action is required.
No boot
device
available
Faulty diskette, diskette-
drive subsystem, hard-disk
drive, hard-disk drive sub-
system, or no boot disk in
drive A
Replace the diskette or
hard-disk drive. If the prob-
lem persists, replace the
system board.
No boot
sector on
hard-disk
drive
Incorrect configuration set-
tings in System Setup
program, or no operating
system on hard-disk drive
Check the hard-disk drive
configuration settings in
the System Setup
program.
No timer
tick
interrupt
Defective system board
Replace the system board.
7DEOH6\VWHP0HVVDJHV
FRQWLQXHG
0HVVDJH
&DXVH
&RUUHFWLYH$FWLRQ
Summary of Contents for PowerEdge 2300
Page 1: ...ZZZ GHOO FRP HOO 3RZHU GJH 6 VWHPV 6 59 0 18 ...
Page 2: ......
Page 3: ...ZZZ GHOO FRP HOO 3RZHU GJH 6 VWHPV 6 59 0 18 ...
Page 9: ...ix ...
Page 30: ...1 20 Dell PowerEdge 2300 Systems Service Manual ...
Page 48: ...3 12 Dell PowerEdge 2300 Systems Service Manual ...
Page 74: ...4 26 Dell PowerEdge 2300 Systems Service Manual ...
Page 83: ......