Codes and Messages
3-9
Timer chip
counter 2
failed
Defective system board
Replace the system board.
Unexpected
interrupt in
protected
mode
Improperly seated DIMMs
or faulty keyboard/mouse
controller chip (defective
system board)
Remove and reseat the
DIMMs. If the problem
persists, replace the
DIMMs. If the problem still
persists, replace the sys-
tem board.
Unsupported
CPU detected
in SLOT
n
Microprocessor not sup-
ported by system
Install a correct version of
the microprocessor in the
specified microprocessor
connector.
Unsupported
CPU speed in
CMOS
Microprocessor not sup-
ported by BIOS
Upgrade the BIOS.
Write fault
Write fault
on selected
drive
Faulty diskette or hard-disk
drive
Replace the diskette or
hard-disk drive.
7DEOH6\VWHP0HVVDJHV
FRQWLQXHG
0HVVDJH
&DXVH
&RUUHFWLYH$FWLRQ