GPGPU configurations are not supported at 35deg. C of ambient or above.
●
Mellanox 100G NICs are not supported.
For information on the restriction for fresh air condition, see the PowerEdge T640 Technical Specs at
www.dell.com/
poweredgemanuals
Cooling fan matrix
Table 11. Cooling fan matrix
Chassis
FAN1, FAN2
(Standard [STD])
FAN3, FAN4,
FAN5, FAN6
(Standard [STD]/
High performance
[HPR])
FAN_EXT_R,
FAN_EXT_L
Fan configuration
3.5 inch x 8
Yes
-
-
Base configuration
3.5 inch x 18
Yes
Yes (STD)
-
Rich configuration
2.5 inch x 16
Yes
-
-
Base configuration
2.5 inch x 32
Yes
-
-
Base configuration
2.5 inch x 16 + NVMe
Yes
Yes (STD)
-
Rich configuration
Fan redundancy, FA
and high cooling tier
PCIe card
Yes
Yes (STD)
-
Rich configuration
GPGPU card
Yes
Yes (HPR)
Yes
GPU configuration
Removing a middle or rear cooling fan
The procedure for removing a standard and a high performance fans is identical.
Prerequisites
NOTE:
Opening or removing the system cover when the system is on may expose you to a risk of electric shock. Exercise
utmost care while removing or installing cooling fans.
CAUTION:
The cooling fans are hot swappable. To maintain proper cooling while the system is on, replace only
one fan at a time.
1. Follow the safety guidelines listed in
on page 27.
2. Follow the procedure listed in
Before working inside your system
Steps
Press the release tab and lift the cooling fan out of the cooling fan assembly.
56
Installing and removing system components
Summary of Contents for Olympus O-T600
Page 21: ...Figure 16 Configuration and layout 20 Dell EMC PowerEdge T640 overview ...
Page 22: ...Figure 17 Electrical overview Dell EMC PowerEdge T640 overview 21 ...
Page 23: ...Figure 18 Memory information 22 Dell EMC PowerEdge T640 overview ...
Page 24: ...Figure 19 System tasks Dell EMC PowerEdge T640 overview 23 ...