Table 4. Front panel features (continued)
Item
Components
Icon
Description
4
Information tag
N/A
The Information tag is a slide-out label panel that contains system
information such as Service Tag, NIC, MAC address, and so on. If you
have opted for the secure default access to iDRAC, the Information tag
also contains the iDRAC secure default password.
5
USB port 2.0
The USB ports are 4-pin, 2.0-compliant. These ports enable you to
connect USB devices to the system.
6
USB port 3.0
The USB port is USB 3.0 compliant.
7
Optical drive bay
N/A
Enable you to install drives that are supported on your system.
For more information, see the Dell EMC PowerEdge T440 Technical
Specifications on the product documentation page.
8
Drive slot
N/A
Enables you to install TBUs for 8x and 16x backplane configurations, or
drive blank in the empty drive slot to maintain proper system cooling.
9
Physical drives
N/A
3.5-inch drives and 2.5-inch drives/SSDs.
Status LED indicators
NOTE:
The indicators display solid amber if any error occurs.
Figure 6. Status LED indicators
Table 5. Status LED indicators and descriptions
Icon
Description
Condition
Corrective action
Health indicator
The indicator turns solid blue if the
system is in good health.
None required.
The indicator blinks amber, when
the system is:
●
Powered on
●
In standby
●
In any error condition For
example, a failed fan, PSU, or
a drive
Check the System event log or system messages for
the specific issue.
For more information about error messages, see
the
Event and Error Message Reference Guide for
14th Generation Dell EMC PowerEdge Servers
at
.
The POST process is interrupted without any video
output due to invalid memory configurations. See
.
Drive indicator
The indicator turns solid amber if
there is a drive error.
●
Check the System event log to determine if the
drive has an error.
●
Run the appropriate Online Diagnostics test.
Restart the system, and run embedded
diagnostics (ePSA.
Dell EMC PowerEdge T440 system overview
15