Figure 54. Locking in the I/O module
3. Connect the cables into the assigned I/O module ports.
Power up the node
Power up the node as described in
.
Verify the operation of a replacement I/O module
Steps
1. From PowerStore Manager, select
Hardware
.
2. Select the appliance where you replaced the I/O module.
3. On the
Components
card, under
Rear View
, expand
BaseEnclosure
.
4. Expand the node that includes the I/O module, and then select the relevant
IoModule
.
The status of the replacement I/O module should read
Healthy
. If the status is still
Faulted
, wait a few minutes and
refresh PowerStore Manager. If the status does not change, ensure that the I/O module is correctly seated, or contact your
service provider.
Return a faulted part
About this task
For US customers, return defective material within five business days. For International customers, return defective material
within 10 business days. The materials required to return your defective part are supplied with the good part shipment.
Steps
1. Package the faulted part in the shipping box that contained the replacement part.
2. Ship the failed part to your service provider as described in the instructions that were included with the replacement part.
3. For more information about returning customer-replaceable parts:
a. Open PowerStore Manager.
b. Click
Settings
on the upper right of the screen.
c. Click
General Support
.
d. Under
Drives, Power Supplies, and Other Parts
, click
Return Part
.
e. If your screen does not show the Return Part link, contact your service provider for instructions.
Replace a fan module
Take the following actions to remove the faulted fan module and install the replacement fan module into the system.
Base enclosure service procedures