Table 2. Embedded module LEDs (continued)
LED
Location
State
Description
Off
No link established.
Port link
Green
Link up with high speed.
Amber
Link up with degraded speed.
Off
Link down.
Node fault
Amber
Fault has occurred in the node or one of
its components.
Off
No fault has occurred. Normal operation.
Node power
Green
Node is on (main power).
Off
Node is off.
Unsafe to remove
White
Do not remove the node. Improper
removal could cause data loss.
Off
Safe to remove the node when the node
has been properly prepared.
Power down the node
Power down the node as described in
.
Remove a faulted embedded module
Steps
1. Label and disconnect all cables that are attached to the embedded module.
CAUTION:
Do not pull the node from the base enclosure. Pulling the node from the base enclosure disrupts
the system cache.
2. Push the orange tab on the embedded module to release the lever.