Determine rail kit that will be used
Unpack the rail kit and determine which type of rail kit is being used for installation of
the server.
Static Rail Kit -- Install the static rail kit and server as described in the procedures
later in this chapter.
Sliding Rail Kit -- Install the sliding rail kit and server as described in the procedures
later in this chapter.
Install the static rail assemblies in the cabinet
This procedures describes installation of the static rail assemblies in the cabinet.
Procedure
1. Position the left and right rail end pieces labeled FRONT facing inward and
orient each end piece to seat in the holes on the front side of the vertical
cabinet flanges (1).
2. Align each end piece in the bottom and top holes of the desired U spaces (2).
3. Engage the back end of the rail until it fully seats on the vertical cabinet flange
and the latch clicks into place. Repeat these steps to position and seat the front
end piece on the vertical cabinet flange (3).
Note
To remove the rails, pull on the latch release button on the end piece midpoint
and unseat each rail (4).
Figure 25 Installing static rail assemblies
2U1N Configuration Equipment Installation
Determine rail kit that will be used
63
Summary of Contents for EMC VxFlex Ready Node 13G
Page 1: ...Dell EMC VxFlex Ready Node 13G Hardware Installation Guide 302 002 955 REV 05 ...
Page 6: ...FIGURES 6 Hardware Installation Guide ...
Page 8: ...TABLES 8 Hardware Installation Guide ...
Page 16: ...1U1N Procedures 16 Hardware Installation Guide ...
Page 58: ...2U1N Procedures 58 Hardware Installation Guide ...
Page 69: ...Figure 32 Install the bezel 2U1N Configuration Equipment Installation Install bezel 69 ...
Page 70: ...2U1N Configuration Equipment Installation 70 Hardware Installation Guide ...