Faulted parts appear in red in the image of the system, and report a status of
Faulted
in the State field.
Embedded module LEDs
Use the fault LEDs to identify the faulted part.
Figure 30. Embedded module LEDs
Table 2. Embedded module LEDs
LED
Location
State
Description
Embedded module fault
Amber
Embedded module has faulted.
Off
No fault has occurred, normal operation.
Ethernet port link
Green
Link established.
Off
No link established.
Ethernet port activity
Amber blinking
Port activity.
Off
No port activity.
SAS port and activity link
Blue
SAS port link is up.
Off
No link established.
Port link
Green
Link up with high speed.
Amber
Link up with degraded speed.
Off
Link down.
Node fault
Amber
Fault has occurred in the node or one of its
components.
Off
No fault has occurred. Normal operation.
Node power
Green
Node is on (main power).
Off
Node is off.
Unsafe to remove
White
Do not remove the node. Improper removal
could cause data loss.
Off
Safe to remove the node when the node
has been properly prepared.
Power down the node
Power down the node as described in
.
Remove a faulted embedded module
Steps
1. Label and disconnect all cables that are attached to the embedded module.
Base enclosure service procedures
35