TDP
(W)
Proces
sor
model
number
Suppor
ted
heat
sinks
Max
DIMM
count
per
CPU
12x
3.5”
HDDs
enclosu
re
8x 3.5”
HDDs
enclosu
re
4x 3.5”
HDDs
enclosu
re
24x
2.5”
HDDs
enclosu
re
20x
2.5”
HDDs
enclosu
re
16x
2.5”
HDDs
enclosu
re
12x
2.5”
HDDs
enclosu
re
8x 2.5”
HDDs
enclosu
re
4x 2.5”
HDDs
enclosu
re
No
back
plane
enclosu
re
8176
CPU1:
JYKMM CPU1: 8
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
8176M
CPU1:
JYKMM CPU1: 8
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
8170M
CPU1:
JYKMM CPU1: 8
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
8170
CPU1:
JYKMM CPU1: 8
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
155W
6144
CPU1:
FMM2
M
CPU1: 6
30°C/
86°F
30°C/
86°F
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
150W
6148
CPU1:
JYKMM CPU1: 8
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
6142
CPU1:
JYKMM CPU1: 8
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
6136
CPU1:
JYKMM CPU1: 8
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
8164
CPU1:
JYKMM CPU1: 8
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
8160M
CPU1:
JYKMM CPU1: 8
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
8160
CPU1:
JYKMM CPU1: 8
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
140W
6132
CPU1:
JYKMM CPU1: 8
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
6152
CPU1:
JYKMM CPU1: 8
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
6140M
CPU1:
JYKMM CPU1: 8
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
6140
CPU1:
JYKMM CPU1: 8
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
130W
6134
CPU1:
JYKMM CPU1: 8
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
125W
6126
CPU1:
JYKMM CPU1: 8
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
8153
CPU1:
JYKMM CPU1: 8
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
28
Technical specifications
Summary of Contents for EMC PowerEdge C6420
Page 1: ...Dell EMC PowerEdge C6420 Regulatory Model E43S Series Regulatory Type E43S001 ...
Page 8: ...Figure 1 Supported configurations for PowerEdge C6420 8 PowerEdge C6420 overview ...
Page 64: ...Figure 12 Removing a sled 64 Installing and removing system components ...
Page 66: ...Figure 14 Installing a sled 66 Installing and removing system components ...