Manual Rebuild – Batch Mode
Perform the following steps to rebuild more than one drive:
1
Choose
Rebuild
from the
Management Menu
.
A device selection window displays the devices connected to the
current controller. The failed drives have
FAIL
indicators.
2
Press the arrow keys to select the drives to be rebuilt.
3
After you select the physical drives, press <F10>.
4
Type
Yes
at the confirmation prompt.
The indicators for the selected drives change to
REBLD
. Rebuilding
can take some time, depending on the number of drives you have
selected and their capacities.
5
When rebuild is complete, press any key to continue.
6
Press <Esc> to display the
Management Menu
.
Exiting Dell Manager
To exit Dell Manager, press <Esc> from the main menu and choose
Yes
at
the prompt. A message appears if uninitialized logical drives remain in the
system.
Summary of Contents for DC, 3
Page 8: ...6 w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 20: ...18 Figures ...
Page 25: ...SE CT ION 1 Overview PERC 3 Overview PERC 3 Features ...
Page 30: ...28 Overview w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 43: ...SE CT ION 3 RAID Levels Overview Selecting a RAID Level RAID 0 RAID 1 RAID 5 RAID 10 RAID 50 ...
Page 150: ...148 PERC 3 QC Hardware Installation w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 214: ...212 Appendix A SCSI Cables and Connectors w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 215: ...S EC T IO N 1 5 Appendix B Warranties and Return Policy ...
Page 248: ...246 Glossary w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 253: ......
Page 254: ...w w w d e l l c o m s u p p o r t d e l l c o m Printed in the U S A P N 5C229 Rev A04 ...