PERC 3/DC or PERC 3/DCL Hardware Installation
129
F i g u r e 9 - 6 . C o n n e c t i n g S C S I C a b l e s t o P E R C 3 / D C a n d
3 / D C L
Connect SCSI Devices
When connecting SCSI devices:
1
Disable termination on any SCSI device that is
not
at the end of the
SCSI bus.
If the cable is terminated, do not terminate SCSI devices.
2
Configure all SCSI devices to supply TermPWR.
3
Set proper target IDs (TIDs) for all SCSI devices.
4
The cable length should not exceed 12 meters for LVD and 160M
SCSI devices.
Cable Suggestions
SCSI disk subsystem throughput can impaired if SCSI cabling is not
optimized. Dell suggests using the following:
• Actively terminated cables
• Dell-approved cables
Pin 1
Pin 1
Summary of Contents for DC, 3
Page 8: ...6 w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 20: ...18 Figures ...
Page 25: ...SE CT ION 1 Overview PERC 3 Overview PERC 3 Features ...
Page 30: ...28 Overview w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 43: ...SE CT ION 3 RAID Levels Overview Selecting a RAID Level RAID 0 RAID 1 RAID 5 RAID 10 RAID 50 ...
Page 150: ...148 PERC 3 QC Hardware Installation w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 214: ...212 Appendix A SCSI Cables and Connectors w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 215: ...S EC T IO N 1 5 Appendix B Warranties and Return Policy ...
Page 248: ...246 Glossary w w w d e l l c o m s u p p o r t d e l l c o m ...
Page 253: ......
Page 254: ...w w w d e l l c o m s u p p o r t d e l l c o m Printed in the U S A P N 5C229 Rev A04 ...