8-10
Dell PowerEdge 6100/200 System Installation and Troubleshooting Guide
Both microprocessor module sockets must be filled
regardless of how many microprocessors are installed;
you must use a bus termination module in the second
socket if you have only one microprocessor installed.
Note that both sockets on the primary module should be
populated before populating the sockets on the secondary
module. Table 8-2 shows the valid microprocessor
configurations.
Similarly, both of the microprocessor module connectors
on the system board must be populated. For example, if
you are using only one or two microprocessors on one
microprocessor module (thus populating the primary
connector), the second connector on the system board
must also be populated with either another micro-
processor module or a terminator card.
Table 8-2. Valid Microprocessor Configurations
Number of
Microprocessors
Microprocessor Module
(Primary)
Microprocessor Module
(Secondary)
1
1 microprocessor in lower socket
bus termination module
1
1 microprocessor in lower socket
empty microprocessor module
2
2 microprocessors in sockets
bus termination module
2
2 microprocessors in sockets
empty microprocessor module
1
2
1
3
4
2
4
3
Summary of Contents for 6100
Page 1: ... HOO 3RZHU GJH 6 VWHP 167 7 21 1 7528 6 227 1 8 ...
Page 8: ...x ...
Page 18: ...xx ...
Page 20: ...xxiv DELL CONFIDENTIAL Preliminary 12 17 96 ...
Page 32: ...3 6 Dell PowerEdge 6100 200 System Installation and Troubleshooting Guide ...
Page 52: ...5 18 Dell PowerEdge 6100 200 System Installation and Troubleshooting Guide ...
Page 78: ...7 22 Dell PowerEdge 6100 200 System Installation and Troubleshooting Guide ...
Page 124: ...11 16 Dell PowerEdge 6100 200 System Installation and Troubleshooting Guide ...
Page 134: ...B 8 Dell PowerEdge 6100 200 System Installation and Troubleshooting Guide ...