132
Save FRU Button
This button allows you to save the currently displayed FRU to a file. If the save fails because the
file cannot be created, this message is displayed:
Unable to create save file
If an error occurs while writing information to the file, this message is displayed:
Error saving the FRU data to the file
Open FRU Button
This button allows you to load a currently saved FRU file. Upon selecting this option, all currently
loaded FRUs are deleted from the screen and the loaded FRU is displayed. If the file to open is not
a valid FRU file, this message is displayed:
Invalid FRU file
If there is an error while reading the FRU from the file, this message is displayed:
Error reading FRU from file
Opening a FRU file will not affect the FRU properties.
Properties Button
This button will display the system FRU properties in a dialog. Included in the properties are: IPMI
version, Number of FRUs in the system, and Number of IPMI formatted FRUs in the system.
There is also a note to notify you that only IPMI formatted FRUs are displayed.
Reload Button
This will clear the currently loaded FRUs and refresh the FRUs from the system. This load
procedure is identical to the load procedure when the viewer is opened.
Help Button
This displays the SMU context sensitive help for the FRU Viewer.