b. Set SR-IOV Global Enable to Enabled.
c. Verify that the Internal USB Port parameter is set to Off.
d. Click Back to return to the System BIOS Settings screen.
10. From the System BIOS Settings screen, click Finish, Yes, and then OK to
return to the System Setup Main Menu screen.
11. Select Finish to exit the BIOS and apply all settings post boot.
Results
The BMC (iDRAC) IP and server BIOS address configuration is complete.
Verify the status of the system hardware, storage
controller, and disks
Verify the status of the system hardware, storage controller, and disks on a ScaleIO
Ready Node server.
Before you begin
Ensure that you know:
l
The IP address of the BMC (iDRAC) port
l
The username and password for the BMC (iDRAC) portal (default username and
password are root and password)
Procedure
1. From a browser, go to http://
<BMC/iDRAC_IP_address>.
The DELL Console Login window is displayed.
2. Type the user name and password, then click Login.
The Dashboard displays the high-level status of all hardware devices in the
System Health pane.
In an ideal scenario, all hardware sensors should appear in green.
3. To view the event log (SEL log), on the Dashboard select Maintenance
>
System Event Logs.
The System Event Log pane is displayed with color-coded severity levels.
4. Ensure that any power supply- and fan-related events in the event log are non-
repetitive. Repetitive events may be due to the intermittent nature of faults,
such as poor physical connections.
For repetitive events, it is recommended that you remove the relevant hardware
module and replace it in its socket.
5. In the navigation pane, select Storage
>
Overview
>
Controller.
A table displays the controller-related information, with the controller type in
the Name column. For example:
PERC H740P Adapter (PCI Slot 4)
6. In the navigation pane, select Storage
>
Physical Disks.
A table displays information regarding the physical disks, and an option to
Blink/Unblink the selected disk.
Configuring the Hardware
20
Hardware Configuration and Operating System Installation Guide - Windows Servers
Summary of Contents for 302-004-341
Page 6: ...FIGURES 6 Hardware Configuration and Operating System Installation Guide Windows Servers ...
Page 8: ...TABLES 8 Hardware Configuration and Operating System Installation Guide Windows Servers ...
Page 70: ...Index 70 Hardware Configuration and Operating System Installation Guide Windows Servers ...